background image

English

2

Start or stop the air conditioner with the remote 
controller. Never use the power circuit breaker for this 
purpose. 

Otherwise, it may cause a fire or water leakage. 
Furthermore, if an automatic restart control is provided 
against power failure and the power is recovered, the fan 
will rotate suddenly and may cause injury.

Do not use the air conditioner in the atmosphere 
contaminated with oil vapor, such as cooking oil or 
machine oil vapor.

Oil vapor may cause crack damage to the air conditioner, 
electric shocks, or a fire.

Do not use flammable materials (e.g., hairspray or 
insecticide) near the air conditioner.
Do not clean the air conditioner with organic solvents 
such as paint thinner.

The use of organic solvents may cause crack damage to 
the air conditioner, electric shocks, or a fire.

Do not use the air conditioner in places with excessive 
oily smoke, such as cooking rooms, or in places with 
flammable gas, corrosive gas, or metal dust.

Using the air conditioner in such places may cause a fire or 
air conditioner failures.

Beware of a fire in case of refrigerant leakage.

If the air conditioner is not operating correctly, i.e. not 
generating cool or warm air, refrigerant leakage could be 
the cause. Consult your local dealer for assistance. The 
refrigerant used for the air conditioner is safe and normally 
does not leak. However, if the refrigerant leaks and gets in 
contact with a naked burner, heater or cooker, it may 
generate hazardous compounds. Turn off the air 
conditioner and call your local dealer. Turn on the air 
conditioner after the qualified service person makes sure to 
confirm that the leakage is repaired.

Do not place objects, including rods, your fingers, etc., 
in the air inlet or outlet.

Injury may result due to contact with the air conditioner’s 
highspeed fan blades.

Consult your local dealer regarding cleaning the inside 
of the air conditioner.

Improper cleaning may cause breakage of plastic parts, 
water leakage and other damage as well as electric shocks.

Be aware that prolonged, direct exposure to cool or 
warm air from the air conditioner, or to air that is too 
cool or too warm can be harmful to your physical 
condition and health.
Consult your local dealer about installation work.

Doing the work yourself may result in water leakage, 
electric shocks or a fire.

Contact professional personnel about attachment of 
accessories and be sure to use only accessories 
specified by the manufacturer.

If a defect results from your own workmanship, it may result 
in water leakage, electric shocks or a fire.

Consult your local dealer regarding relocation and 
reinstallation of the air conditioner.

Improper installation work may result in leakage, electric 
shocks or a fire.

Be sure to earth the air conditioner.

Do not earth the air conditioner to a utility piping, lightning 
conductor or telephone earth lead.
Imperfect earthing may result in electric shocks or a fire.
A high surge current from lightning or other sources may 
cause damage to the air conditioner.

Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may result in 
electric shocks or a fire.

Be sure to use a dedicated power supply for the air 
conditioner.

The use of any other power supply may cause heat 
generation, a fire, or air conditioner failures.

Consult your local dealer regarding what to do in case 
of refrigerant leakage.

When the air conditioner is installed in a small room, it is 
necessary to take proper measures so that the amount of 
any leaked refrigerant does not exceed the concentration 
limit in the event of a leakage. Otherwise, this may lead to 
an accident due to oxygen depletion.

The appliance shall be stored so as to prevent 
mechanical damage and in a well-ventilated room 
without continuously operating ignition sources 
(example: open flames, an operating gas appliance or 
an operating electric heater) and have a room size as 
specified in installation manual (only for R32 
refrigerant).

CAUTION

Children should be watched so that they do not play 
with the indoor unit or its remote controller.

Accidental operation by a child may result in injury or 
electric shocks.

Do not allow a child to mount on the outdoor unit or 
avoid placing any object on it.

Falling or tumbling may result in injury.

Do not let children play on or around the outdoor unit.

If they touch the unit carelessly, injury may be caused.

Be sure that children, plants or animals are not 
exposed directly to airflow from the indoor unit, as 
adverse effects may ensue.
Do not place flammable sprays or operate spray 
containers near the air conditioner as this may result in 
a fire.
Do not wash the air conditioner or the remote 
controller with water, as this may result in electric 
shocks or fire.
Do not place water containers (flower vases, etc.) on 
the indoor unit, as this may result in electric shocks or 
a fire.
Do not put flammable containers, such as spray cans, 
within 1 m from the air outlet.

The containers may explode because the warm air from the 
indoor or outdoor unit will affect them.

Turn off the power when the air conditioner is not used 
for long periods of time.

Otherwise, the air conditioner may get hot or catch on a fire 
due to dust accumulation.

Do not place objects in direct proximity of the outdoor 
unit and do not let leaves and other debris accumulate 
around the unit.

Leaves are a hotbed for small animals which can enter the 
unit. Once in the unit, such animals can cause 
malfunctions, smoke or a fire when making contact with 
electrical parts.

Before cleaning, be sure to stop the air conditioner 
operation, turn the power circuit breaker off.

Otherwise, an electric shocks and injury may result.

To avoid electric shocks, do not operate with wet 
hands.

4PEN465543-1D.book  Page 2  Monday, February 25, 2019  9:26 AM

Summary of Contents for RZAG100

Page 1: ...OPERATION MANUAL FUA71AVEB9 FUA100AVEB9 FUA125AVEB9 Split system air conditioners 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Page 2: ...can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruct...

Page 3: ...a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge current from lightning or other sources may cause damage to the ai...

Page 4: ...animals or works of art as this may adversely affect the performance quality and or longevity of the object concerned Do not install the air conditioner at any place where there is a danger of flammab...

Page 5: ...ontroller when used as simulta neous operation A Pair system or simultaneous operation system B Multi system 1 Unit with remote controller 2 Unit without remote controller when used as simulta neous o...

Page 6: ...ure The setting temperature range of the remote controller is 16 C 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for installation Is the air conditioner installed at a well...

Page 7: ...your system type To protect the air conditioner turn on the main power switch 6 hours before operation Do not shut off the power supply during seasonal use of the air conditioner This is required in...

Page 8: ...irection becomes horizontal The remote controller displays the fan speed and airflow direction that are set CHARACTERISTICS OF THE PROGRAM DRY OPERATION This operation lowers the humidity without lowe...

Page 9: ...r operates Prevent direct sunlight from the window by using curtains or blinds during the COOLING OPERATION Keep doors and windows closed If the doors and windows remain open room air will flow out an...

Page 10: ...nstable it may cause injuries due to fall and stumbling NOTE Do not remove the air filter unless for cleaning It may cause failure Do not attach substance such as paper towels other than the specified...

Page 11: ...e closing the suction grille confirm if the strap is not sticking out from the side of the suction grille If the air filter is extremely contaminated wash it with neutral detergent using a soft brush...

Page 12: ...HAT TO DO WHEN START UP AFTER A LONG STOP Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and...

Page 13: ...off the power circuit breaker during seasonal use of the HEATING OPERATION I THE AIR CONDITIONER DOES NOT OPERATE The air conditioner does not restart immediately after the ON OFF button is pressed T...

Page 14: ...t swing when the remote controller displays the swing operation HEATING OPERATION This is because the airflow direction is controlled so it is horizontal direction after the operation starts or when t...

Page 15: ...by temperature change makes this noise VIII DUST FROM THE INDOOR UNITS Dust may blow out from the unit after starting operation from long resting time Dust absorbed by the unit blows out IX THE INDOOR...

Page 16: ...to an appropriate temperature fan speed and airflow direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and airflow direction Check if the doors or the...

Page 17: ...local and national legislation Units and waste batteries must be treated at a specialized treatment facility for re use recycling and recovery By ensuring correct disposal you will help to prevent pot...

Page 18: ...4P465543 1D 2019 02 Copyright 2017 Daikin 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Reviews: