background image

13

English

• The remote controller displays "

", 

and airflow stops.

This is because the air conditioner 
automatically switches to the DEFROST 
OPERATION to prevent a decrease in 
heating capacity when frost on the outdoor 
unit increases.
After maximum 10 minutes, the air 
conditioner returns to its original operation.

II. THE OPERATION SOMETIMES STOPS

• The remote controller displays "U4" and 

"U5", and the operation stops. However, it 
will restart in a few minutes.

This is because communication between the 
indoor and outdoor units or indoor units and 
remote controllers is shut off and stopped 
due to noise caused by devices other than 
the air conditioner.
When the electrical noise decreases, the air 
conditioner automatically restarts.

III. THE FAN SPEED IS DIFFERENT FROM THE 

SETTING

• Pressing the fan speed control button 

does not change the fan speed.

During the COOLING OPERATION, the low 
fan speed or a gentle wind is used to prevent 
the discharge of melt water. 
During the DEFROST OPERATION 
(HEATING OPERATION), the wind from the 
air conditioner stops to prevent air discharge 
directly toward your body. After a while, the 
fan speed can be changed.
(The fan speed cannot be set for the 
PROGRAM DRY OPERATION.)
When the room temperature reaches the set 
temperature during the HEATING 
OPERATION, the outdoor unit stops and the 
indoor unit goes into gentle wind. 
It takes some time until the fan speed 
changes.
Raise the set temperature. 
After a while, the fan speed changes.

IV. THE AIRFLOW DIRECTION IS DIFFERENT 

FROM THE SETTING, OR THE AIRFLOW 
DIRECTION IS DIFFERENT FROM THE 
DISPLAY ON THE REMOTE CONTROLLER

• The horizontal blades do not swing when 

the remote controller displays the swing 
operation.

<HEATING OPERATION>

This is because the airflow direction is 
controlled so it is horizontal direction after 
the operation starts or when the indoor 
temperature is higher than the set 
temperature to prevent air discharge 
directly toward your body.
After a while, the swing operation starts.
(Refer to "

MOVEMENT OF THE 

HORIZONTAL BLADE

" on page 8.)

• The airflow direction display of the 

remote controller differs from the actual 
operation of the horizontal blades.

<COOLING and PROGRAM DRY 
OPERATIONS>

When the operation in a downward airflow 
direction is set, the airflow direction differs 
from the display for a period of time to 
prevent condensation on the horizontal 
blades.

<HEATING OPERATION>

This is because the airflow direction is 
controlled so it is horizontal direction after 
the operation starts or when the indoor 
temperature is higher than the set 
temperature to prevent air discharge 
directly toward your body.
After a while, the airflow direction changes 
to the set direction.
(Refer to "

MOVEMENT OF THE 

HORIZONTAL BLADE

" on page 8.)

V. HORIZONTAL BLADES DO NOT CLOSE

• The horizontal blades do not close even 

when operation stops.

This is because the horizontal blades close 
once airflow from the air conditioner stops.
After a while, the horizontal blades close.

VI. WHITE MIST COMES OUT OF THE AIR 

CONDITIONER

• When humidity is high during the 

COOLING OPERATION. (In oily or dusty 
places)

If the inside of an indoor unit is extremely 
contaminated, the temperature distribution 
inside a room becomes uneven.
It is necessary to clean the inside of the 
indoor unit. 
Ask your local dealer for details on cleaning 
the indoor unit. 
This cleaning requires a qualified service 
person.
Check the usage environment.

4PEN465543-1D.book  Page 13  Monday, February 25, 2019  9:26 AM

Summary of Contents for RZAG100

Page 1: ...OPERATION MANUAL FUA71AVEB9 FUA100AVEB9 FUA125AVEB9 Split system air conditioners 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Page 2: ...can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruct...

Page 3: ...a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge current from lightning or other sources may cause damage to the ai...

Page 4: ...animals or works of art as this may adversely affect the performance quality and or longevity of the object concerned Do not install the air conditioner at any place where there is a danger of flammab...

Page 5: ...ontroller when used as simulta neous operation A Pair system or simultaneous operation system B Multi system 1 Unit with remote controller 2 Unit without remote controller when used as simulta neous o...

Page 6: ...ure The setting temperature range of the remote controller is 16 C 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for installation Is the air conditioner installed at a well...

Page 7: ...your system type To protect the air conditioner turn on the main power switch 6 hours before operation Do not shut off the power supply during seasonal use of the air conditioner This is required in...

Page 8: ...irection becomes horizontal The remote controller displays the fan speed and airflow direction that are set CHARACTERISTICS OF THE PROGRAM DRY OPERATION This operation lowers the humidity without lowe...

Page 9: ...r operates Prevent direct sunlight from the window by using curtains or blinds during the COOLING OPERATION Keep doors and windows closed If the doors and windows remain open room air will flow out an...

Page 10: ...nstable it may cause injuries due to fall and stumbling NOTE Do not remove the air filter unless for cleaning It may cause failure Do not attach substance such as paper towels other than the specified...

Page 11: ...e closing the suction grille confirm if the strap is not sticking out from the side of the suction grille If the air filter is extremely contaminated wash it with neutral detergent using a soft brush...

Page 12: ...HAT TO DO WHEN START UP AFTER A LONG STOP Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and...

Page 13: ...off the power circuit breaker during seasonal use of the HEATING OPERATION I THE AIR CONDITIONER DOES NOT OPERATE The air conditioner does not restart immediately after the ON OFF button is pressed T...

Page 14: ...t swing when the remote controller displays the swing operation HEATING OPERATION This is because the airflow direction is controlled so it is horizontal direction after the operation starts or when t...

Page 15: ...by temperature change makes this noise VIII DUST FROM THE INDOOR UNITS Dust may blow out from the unit after starting operation from long resting time Dust absorbed by the unit blows out IX THE INDOOR...

Page 16: ...to an appropriate temperature fan speed and airflow direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and airflow direction Check if the doors or the...

Page 17: ...local and national legislation Units and waste batteries must be treated at a specialized treatment facility for re use recycling and recovery By ensuring correct disposal you will help to prevent pot...

Page 18: ...4P465543 1D 2019 02 Copyright 2017 Daikin 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...