When the suction grille is extremely contaminated

Spray the detergent for a ventilating fans and 
ranges directly to the suction grille, and keep it 
under that condition for about 10 minutes.
After that, carefully wash the suction grille with 
water.

NOTE 

• Do not wash the suction grille with warm 

water of 50°C or higher.
It may cause discoloration and deformation.

• When drying the suction grille, do not heat it 

with fire. It may cause burning.

• Do not use such as gasoline, benzine, thinner, 

polishing powder and liquid insecticide sold 
in the market.
It may cause discoloration and deformation.

5. Attach the air filter.

Refer to step 4 of "

HOW TO CLEAN THE AIR 

FILTER

" on page 9.

6. Attach the suction grille.

Attach the suction grille in the reverse order 
mentioned in step 2.

7. Close the suction grille.

Simultaneously slide the 2 knobs in the reverse 
order mentioned in step 1, slowly lift the suction 
grille and securely fix it.

HOW TO CLEAN OUTSIDE PANELS AND 
REMOTE CONTROLLER

Wipe them with a dry soft cloth.

When the stain cannot be wiped off, dip the cloth 
in the neutral detergent diluted with water and 
twist the cloth. 
After wiping off stain with this cloth, wipe them 
with dry cloth.

NOTE 

• Do not use such as gasoline, benzine, thinner, 

polishing powder and liquid insecticide sold 
in the market.
It may cause discoloration and deformation.

• Do not wash them with warm water of 50°C or 

higher.
It may cause discoloration and deformation.

CLEANING BEFORE AND AFTER 
SEASONAL USE

WHAT TO DO WHEN START UP AFTER A 
LONG STOP

Confirm the following.

Check that the air inlet and outlet of indoor and 
outdoor unit are not blocked.
Remove any obstacle.
Obstacles decrease the fan speed, and cause 
performance decrease and breakage of the 
devices.

Clean the air filter.

After cleaning the air filter, make sure to attach it.
(Refer to "

MAINTENANCE (FOR SERVICE 

PERSONNEL)

" on page 9.)

For information on how to install, remove, or clean 
a optional sold air filter, refer to the user’s manual 
attached to the air filter.

Turn off the indication "

" or "Time to clean 

filter" displayed on the remote controller after 
turning on the power.

For details, refer to the operation manual attached 
to the remote controller.
The indication can be turned off whether in 
operation or at stop. 

Turn on the power circuit breaker at least 
6 hours before operation.

This is required in order to activate the air 
conditioner smoothly, and to protect the air 
conditioner.

The display on the remote controller will be shown 
when the power circuit breaker is turned on.

HEATING OPERATION within 6 hours after 
power is supplied to the air conditioner.

Some model series perform the following operation 
to protect the devices.
If the HEATING OPERATION is performed within 
6 hours after power is supplied to the air conditioner, 
the indoor fan stops for about 10 minutes during the 
outdoor unit operation to protect the devices.
The above operation is performed not only for 
installation, but every time the power circuit breaker 
is turned off/on.
For comfortable use, do not turn off the power circuit 
breaker during seasonal use of the HEATING 
OPERATION.

4PEN465543-1D.book  Page 11  Monday, February 25, 2019  9:26 AM

Summary of Contents for RZAG100

Page 1: ...OPERATION MANUAL FUA71AVEB9 FUA100AVEB9 FUA125AVEB9 Split system air conditioners 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Page 2: ...can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruct...

Page 3: ...a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge current from lightning or other sources may cause damage to the ai...

Page 4: ...animals or works of art as this may adversely affect the performance quality and or longevity of the object concerned Do not install the air conditioner at any place where there is a danger of flammab...

Page 5: ...ontroller when used as simulta neous operation A Pair system or simultaneous operation system B Multi system 1 Unit with remote controller 2 Unit without remote controller when used as simulta neous o...

Page 6: ...ure The setting temperature range of the remote controller is 16 C 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for installation Is the air conditioner installed at a well...

Page 7: ...your system type To protect the air conditioner turn on the main power switch 6 hours before operation Do not shut off the power supply during seasonal use of the air conditioner This is required in...

Page 8: ...irection becomes horizontal The remote controller displays the fan speed and airflow direction that are set CHARACTERISTICS OF THE PROGRAM DRY OPERATION This operation lowers the humidity without lowe...

Page 9: ...r operates Prevent direct sunlight from the window by using curtains or blinds during the COOLING OPERATION Keep doors and windows closed If the doors and windows remain open room air will flow out an...

Page 10: ...nstable it may cause injuries due to fall and stumbling NOTE Do not remove the air filter unless for cleaning It may cause failure Do not attach substance such as paper towels other than the specified...

Page 11: ...e closing the suction grille confirm if the strap is not sticking out from the side of the suction grille If the air filter is extremely contaminated wash it with neutral detergent using a soft brush...

Page 12: ...HAT TO DO WHEN START UP AFTER A LONG STOP Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and...

Page 13: ...off the power circuit breaker during seasonal use of the HEATING OPERATION I THE AIR CONDITIONER DOES NOT OPERATE The air conditioner does not restart immediately after the ON OFF button is pressed T...

Page 14: ...t swing when the remote controller displays the swing operation HEATING OPERATION This is because the airflow direction is controlled so it is horizontal direction after the operation starts or when t...

Page 15: ...by temperature change makes this noise VIII DUST FROM THE INDOOR UNITS Dust may blow out from the unit after starting operation from long resting time Dust absorbed by the unit blows out IX THE INDOOR...

Page 16: ...to an appropriate temperature fan speed and airflow direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and airflow direction Check if the doors or the...

Page 17: ...local and national legislation Units and waste batteries must be treated at a specialized treatment facility for re use recycling and recovery By ensuring correct disposal you will help to prevent pot...

Page 18: ...4P465543 1D 2019 02 Copyright 2017 Daikin 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Reviews: