background image

English

10

3. Clean the filter.

Clean the contamination with a vacuum cleaner 
or wash it with water.

NOTE 

• Do not wash the air filter with water of 50°C or 

higher. 
It may cause decolorization and deformation. 

• Do not heat the filter with fire. 

It may cause burning.

4. Attach the air filter. 

Attach the air filter in the reverse order 
mentioned in step 2.

5. Close the suction grille.

Simultaneously slide the two knobs, slowly lift 
the suction grille and securely fix it in the reverse 
order mentioned in step 1.

6. Turn off the indication "

" or "Time to 

clean filter" displayed on the remote 
controller after turning on the power. 

For details, refer to the operation manual 
attached to the remote controller.
The indication can be turned off whether in 
operation or at stop.

NOTE 

When closing the suction grille, the strap is likely 
to be sandwiched.

Before closing the suction grille, confirm if the 
strap is not sticking out from the side of the 
suction grille.

If the air filter is 
extremely 
contaminated, 
wash it with 
neutral detergent 
using a soft brush.

After dewatering, 
dry the air filter in 
the shade.

a

Strap

b

Suction grille

a

b

HOW TO CLEAN THE SUCTION GRILLE

1. Open the suction grille.

Simultaneously slide the two knobs, slowly down 
the suction grille.

2. Remove the suction grille.

1

Remove the 4 straps attached to the indoor 
unit. (Refer to the figure shown below.)

2

Open the suction grille to 45° and lift it. Then, 
unhook it from the place to hook. (3 places)

3. Take out the air filter.

Refer to step 2 of "

HOW TO CLEAN THE AIR 

FILTER

" on page 9.

4. Clean the suction grille.

Wash the suction grille with neutral detergent 
using a soft brush and then dewater.

a

knob

a

Place where the straps are to be hooked (A total of 
4 places)

b

Place to hook (3 places)

c

Unhook the hook

d

Place where the straps are to be hooked

Detergent

a

a

a

b

c

d

4PEN465543-1D.book  Page 10  Monday, February 25, 2019  9:26 AM

Summary of Contents for RZAG100

Page 1: ...OPERATION MANUAL FUA71AVEB9 FUA100AVEB9 FUA125AVEB9 Split system air conditioners 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Page 2: ...can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruct...

Page 3: ...a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge current from lightning or other sources may cause damage to the ai...

Page 4: ...animals or works of art as this may adversely affect the performance quality and or longevity of the object concerned Do not install the air conditioner at any place where there is a danger of flammab...

Page 5: ...ontroller when used as simulta neous operation A Pair system or simultaneous operation system B Multi system 1 Unit with remote controller 2 Unit without remote controller when used as simulta neous o...

Page 6: ...ure The setting temperature range of the remote controller is 16 C 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for installation Is the air conditioner installed at a well...

Page 7: ...your system type To protect the air conditioner turn on the main power switch 6 hours before operation Do not shut off the power supply during seasonal use of the air conditioner This is required in...

Page 8: ...irection becomes horizontal The remote controller displays the fan speed and airflow direction that are set CHARACTERISTICS OF THE PROGRAM DRY OPERATION This operation lowers the humidity without lowe...

Page 9: ...r operates Prevent direct sunlight from the window by using curtains or blinds during the COOLING OPERATION Keep doors and windows closed If the doors and windows remain open room air will flow out an...

Page 10: ...nstable it may cause injuries due to fall and stumbling NOTE Do not remove the air filter unless for cleaning It may cause failure Do not attach substance such as paper towels other than the specified...

Page 11: ...e closing the suction grille confirm if the strap is not sticking out from the side of the suction grille If the air filter is extremely contaminated wash it with neutral detergent using a soft brush...

Page 12: ...HAT TO DO WHEN START UP AFTER A LONG STOP Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and...

Page 13: ...off the power circuit breaker during seasonal use of the HEATING OPERATION I THE AIR CONDITIONER DOES NOT OPERATE The air conditioner does not restart immediately after the ON OFF button is pressed T...

Page 14: ...t swing when the remote controller displays the swing operation HEATING OPERATION This is because the airflow direction is controlled so it is horizontal direction after the operation starts or when t...

Page 15: ...by temperature change makes this noise VIII DUST FROM THE INDOOR UNITS Dust may blow out from the unit after starting operation from long resting time Dust absorbed by the unit blows out IX THE INDOOR...

Page 16: ...to an appropriate temperature fan speed and airflow direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and airflow direction Check if the doors or the...

Page 17: ...local and national legislation Units and waste batteries must be treated at a specialized treatment facility for re use recycling and recovery By ensuring correct disposal you will help to prevent pot...

Page 18: ...4P465543 1D 2019 02 Copyright 2017 Daikin 4PEN465543 1D book Page 1 Monday February 25 2019 9 26 AM...

Reviews: