SiK401004_A
79
INSTALLATION
3.3 Specification of Connection Pipe
External Diameter
Maximum Length
of Connection
Pipe
Maximum Difference
in Height between
Outdoor and Indoor Unit
Additional
Charge
of Refrigerant
Model
Gas Pipe Liquid Pipe
(m) (m)
(g/m)
RY24PEV1K
R24PEV1K
RY30PEV1K
R30PEV1K
5/8 3/8
30
15
60
RY36PEY1K
R36PEY1K
RY42PEY1K
R42PEY1K
RY48PEY1K
R48PEY1K
3/4 1/2
50
30
120