SiK401004_A
99
MAINTENANCE
Malfunction display: F3 Malfunction of Outdoor Ambient Thermistor
Malfunction display: F4 Malfunction of Exhaust Temp. Thermistor
Yes
Check the direction of
the plug and socket
No
Malfunction of outdoor
ambient thermistor
Check if the
plug of the temperature sensor is
correctly connected with socket on
the mainboard
Replace mainboard of the
indoor unit
Replace temperature
sensor
No
Yes
Yes
Remove the
sensor to check if the resistance
value is ok
Yes
Check the direction of
the plug and socket
No
Malfunction of exhaust
Temp. thermistor
Check if the
plug of the temperature sensor is
correctly connected with socket
on the mainboard
Replace mainboard of the
indoor unit
Replace temperature
sensor
No
Yes
Yes
Remove the
sensor to check if the resistance
value is ok