56
Operation
EN
RoCon UFH
D: Programming the Additional Pump Running Time function
You can program an additional pump running time from 0 to 15 minutes. To disable
the Additional Pump Running Time function, you must set the duration to the value
"0".
The indicator for the switching output Additional Pump Running Time is only dis-
played if the menu Additional Pump Running Time is active or if the function Addi-
tional Pump Running Time is running.
1. Keep pressing the Menu key until the Additional Pump Running Time function
indicator "Pu" is displayed.
2. Hold down the Set key for 3 seconds.
- The digits for the switch on duration blink.
3. Press the Menu key to adjust the required value.
4. Press the Set key to save.
A. Indicator "Menu Additional Pump
Running Time Function" active
B. Switch on duration (0 - 15 minutes)
C. Indicator "Menu" active
D. Switching output Additional Pump
Running Time function active
Fig. 7-18: Programming the Additional Pump Running Time function
A
B
D C