55
Operation
EN
RoCon UFH
C: Setting the interval
If the Interval function is active, the pump is automatically switched on.
The following switching data can be programmed:
• Time
• Weekday
• Duration of interval
- To disable the Interval function, you must set the duration of the interval to
"0".
1. Keep pressing the Menu key until the Interval function screen is displayed.
2. Hold down the Set key for 3 seconds.
- The "Hour" digits flash.
3. Keep pressing the Menu key until the required hour is displayed.
4. Press the Set key to save the hour.
- The "Minute" digits flash.
5. Keep pressing the Menu key until the required minute is displayed.
6. Press the Set key to save.
- The "Duration" digits flash.
7. Keep pressing the Menu key until the required interval (0 to 15 minutes) is dis-
played.
8. Press the Set key to save the interval.
- The "Weekday" digits flash.
9. Keep pressing the Menu key until the required weekday (1 = Monday to
7 = Sunday) is displayed.
10.Press the Set key to save.
A. Menu "Interval function"
B. Time (format: 24 h)
C. Weekday (3 = Wednesday)
D. Indicator "Menu"
E. Indicator "Interval function"
F. Switch on duration of switching output
"Interval" (0 to 15 minutes)
Fig. 7-17: Programming the Interval function
Summary of Contents for RoCon UFH
Page 2: ......
Page 27: ...25 Mounting EN RoCon UFH 6 Refit the cover and close it Fig 5 5 Closing the cover ...
Page 64: ......
Page 126: ......
Page 151: ...25 Montage FR RoCon UFH 6 Accrocher le couvercle et le fermer Fig 5 5 Fermer le couvercle ...
Page 188: ......
Page 213: ...25 Montage NL RoCon UFH 6 Haak de afdekking vast en sluit haar Afb 5 5 Afdekking sluiten ...
Page 250: ......
Page 312: ...008 1706699 00 12 2020 Copyright Daikin www daikin eu ...