45
Operation
EN
RoCon UFH
7.2
Adjusting the room temperature
7.3
Limiting temperature adjustments
The adjustment range of the rotary knob is factory-set to a minimum of +8 °C and a
maximum of +30 °C by means of restrictors. The restrictors can be adjusted to set the
minimum and the maximum adjustable temperature.
1. Turn the cam screw at the product by approximately 90° using a screwdriver.
2. The rotary knob is lifted and can be removed.
1. Adjust the desired tempera-
ture at the room controller.
- Without temperature
reduction: The product
controls the room tempera-
ture to the adjusted value
- With temperature reduc-
tion: The product controls
the room temperature to a
value 4 K below the
adjusted value
Fig. 7-4: Example: adjusted room temperature 21 °C
Fig. 7-5: Removing the rotary knob
90°
Summary of Contents for RoCon UFH
Page 2: ......
Page 27: ...25 Mounting EN RoCon UFH 6 Refit the cover and close it Fig 5 5 Closing the cover ...
Page 64: ......
Page 126: ......
Page 151: ...25 Montage FR RoCon UFH 6 Accrocher le couvercle et le fermer Fig 5 5 Fermer le couvercle ...
Page 188: ......
Page 213: ...25 Montage NL RoCon UFH 6 Haak de afdekking vast en sluit haar Afb 5 5 Afdekking sluiten ...
Page 250: ......
Page 312: ...008 1706699 00 12 2020 Copyright Daikin www daikin eu ...