Front panel

Deodrising catalyst unit

Ionised wire

23

Frequently Asked Questions

Before consulting your dealer, check the following points.

The air quality sensor lamp 

remains red or yellow.

This is due to the dust built up in the air quality 
sensor.
Use a vacuum cleaner to remove the dust from 
the air inlet for the air quality sensor. 

Page 16.

 

The 

fi

 lter lamp lights up or blinks.

Replace the pleated 

fi

 lter with a new one and press the 

fi

 lter reset button for 5 seconds. 

Page 21.

 

The air

fl

 ow rate lamps blink simultaneously.

Disconnect the power plug and remove the obstacle. Reconnect the 
power plug cord and turn the power on. 

Page 25.

 

UNIT lamp lights up.

UNIT1: The plasma ioniser is dirty.
UNIT2: The streamer unit is dirty.
Soak and wash. 

Page 19, 20.

 

The electric dust collection and deodorising functions remarkably 
deteriorate because electricity supply to the ionised wires and 
streamer discharger stops for safety.
Use the unit after cleaning the inside and the “UNIT1” “UNIT2” lamps 
go off. (There are no safety issues even if the lamps are lit.)

Question :

Can the deodorising catalyst unit be washed with water?
Does the unit need to be replaced?

Answer :

No, the deodorising catalyst unit can not be washed with water. (If the unit is washed with water, it will be deformed and 
become unusable.) 
When you have washed the deodorising catalyst unit by mistake, consult your dealer. 
Remove the unit from the main body, and use a vacuum cleaner to remove the dust. It is not necessary to replace the 
deodorising catalyst unit with a new one.
If odour is a concern, lightly wet the surface of the deodorising catalyst unit using an atomiser, and then dry it in a shaded 
and well-ventilated place (about 1 day). 

Question :

The sensitivity of the air quality sensor seems 
low.

Answer :

This is because the reaction time of the air quality sensor 
differs depending on the size of the room. 
If the unit is installed at a lower position in the room, 
reaction to the smoke of cigarettes or other items may be 
bad. 
Change the installation site of the unit or adjust the 
sensitivity of the air quality sensor. 

Page 22.

 

Question :

What should you do if the ionised wires are 
cut?

Answer :

If the ionised wires are cut, replacement is necessary.
Consult your dealer. Do not replace the ionised wires 
by yourself.

“If these lamps light or blink”

 

„

01_EN_3P276413-2C.indd   23

01_EN_3P276413-2C.indd   23

9/27/2011   1:21:04 PM

9/27/2011   1:21:04 PM

Summary of Contents for MC70LBFVM

Page 1: ...Air Purifier OPERATION MANUAL Floor Standing Wall hanging Type MODEL MC70LBFVM English 00_CV_3P276413 2C indd 1 00_CV_3P276413 2C indd 1 9 17 2011 9 39 03 AM 9 17 2011 9 39 03 AM...

Page 2: ...cle size is quickly caught Deodorising and decomposing odour in the air The streamer discharge decomposes absorbed odour The decomposition cycle that maintains deodorising capability Adsorption The de...

Page 3: ...rational issues You may smell an odour as a particle of ozone is generated The amount is negligible and does not harm your health CONTENTS Read before Operation Features 1 Safety Precautions 3 Name an...

Page 4: ...he base Incomplete connections may lead to electric shock or fire because of overheating Periodically clean the dust and other matter from the power plug with a dry cloth Insulation failure caused by...

Page 5: ...nit Pulling on the power supply cord may lead to fire or electric shock because of short circuits Before long periods of disuse disconnect the power plug from the electrical socket Degraded insulation...

Page 6: ...ets do not urinate on the unit or bite the power supply cord This may lead to electric shock or fire In the event of abuse by pets stop operation disconnect the power plug and consult your dealer Do n...

Page 7: ...lter container Front panel Ventilation fan Ionised wire rear Ionising frame Opposing pole plates Safety guard Unit display Page 7 Page 16 Page 16 Page 15 Streamer unit UNIT2 Page 20 gray Deodorising c...

Page 8: ...ng the front panel and UNIT1 2 Operation directly after reconnecting the power plug When the sensitivity of the air quality sensor is poor change the setting Page 22 The sensitivity of the air quality...

Page 9: ...ur level remains constant without intensifying or weakening the odour sensor may not detect even strong odours The odour sensor may not detect certain types of odours such as pet odours other than amm...

Page 10: ...attach the pleated filter before starting operation Remove the front panel 1 Push the 2 clips right and left and pull the front panel upward and remove it Push Clip 1 each on right and left Front pan...

Page 11: ...s fit the projections into the grooves 4 locations at the bottom of the main unit and press the deodorising catalyst unit into the main unit 2 Press the deodorising catalyst unit until you hear clicki...

Page 12: ...e cleaning the air during heating or cooling operation Keep TVs radios and stereos 2m or more away from the unit The effects of the power circuit inside the unit and cable may cause a distorted TV pic...

Page 13: ...a doctor immediately When discarding batteries cover the terminals of the batteries with tape If mixed with other metal or batteries heat explosion or combustion may occur The replacement target is a...

Page 14: ...ildproof lock by pressing again for about 2 seconds You can also release the childproof lock when you disconnect the power plug once and after 3 seconds or more reconnect the power plug To operate the...

Page 15: ...etting for the airflow rate returns to Auto fan Before cleaning make sure to stop operation and disconnect the power plug Auto fan operation The airflow rate is automatically selected from Quiet Low S...

Page 16: ...e case of heavy dirt wash the prefilter with a soft brush or neutral detergent and dry it well in the shade Dry the prefilter completely before using it because the UNIT1 lamp may light up if any wate...

Page 17: ...nt Do not wash with water If the unit is washed with water it will be deformed and become unusable If the main unit or the air inlet for the air quality odour sensor is clogged with dust use a vacuum...

Page 18: ...m of the main unit and press the deodorising catalyst unit into the main unit Handles Deodorising catalyst unit 1 Fit here 2 Press the deodorising catalyst unit until you hear clicking sound Attach UN...

Page 19: ...and left at the same time makes it easier to remove the opposing pole plate Be careful not to cut the internal ionised wires Opposing pole plates Knob green Knob white Wear rubber gloves Attach Attach...

Page 20: ...t with a piece of cloth soft brush etc Wear rubber gloves Cloth Cotton swab For details 1 Ionising frame 2 Ionised wire Wear rubber gloves Wipe Brush Cloth Rub Wear rubber gloves Rinse in running wate...

Page 21: ...are deformed deodorising capacity diminishes For details 3 Streamer unit Cloth Cotton swab Wear rubber gloves Wipe If detergent remains on UNIT1 or UNIT2 the UNIT1 and UNIT2 lamps do not go off after...

Page 22: ...lter The replacement interval for the pleated filter varies according to how the unit is used and where it is located The filter lamp lights up after about 2 years if the unit is used every day in a h...

Page 23: ...ration again from the beginning Airflow rate lamp Sensitivity To raise the sensitivity Select the Low airflow rate lamp Low High The sensor more readily reacts to dust To lower the sensitivity Select...

Page 24: ...with water Does the unit need to be replaced Answer No the deodorising catalyst unit can not be washed with water If the unit is washed with water it will be deformed and become unusable When you hav...

Page 25: ...large amount of odour generated when starting operation of the unit The odour level of the initial 1 minute is used as the standard for the sensitivity of the odour sensor Operate the unit with an inc...

Page 26: ...d filter is replaced Did you press the filter reset button for 5 seconds Even if the pleated filter is replaced unless you press the filter reset button for 5 seconds the filter lamp does not go off P...

Page 27: ...English 26 MEMO 01_EN_3P276413 2C indd 26 01_EN_3P276413 2C indd 26 9 27 2011 1 21 07 PM 9 27 2011 1 21 07 PM...

Page 28: ...7 3A MC70LBFVM DAIKIN INDUSTRIES LTD Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC DAIKIN TCF 018 E3 10 2010 KEMA Quality B V 82726 KRQ EMC98 4545 EN60335 2 65 Shinri Sada Manager Q...

Page 29: ...3P276413 2C M10B194B 1111 HT Two dimensional bar code is a code for manufacturing 00_CV_3P276413 2C indd 2 00_CV_3P276413 2C indd 2 9 17 2011 9 39 14 AM 9 17 2011 9 39 14 AM...

Reviews: