background image

English

18

Wear rubber gloves to remove and attach the opposing pole plates. 

Hands can be cut on the opposing pole plates and ionised wires.

CAUTION

Removing and attaching the opposing pole plates

 

„

UNIT1

Opposing pole plates

Ionised wire

Ionising frame

Front panel

Remove

Remove the front panel and UNIT1. 

Page 17.

 

Remove the opposing pole plates from 

the rear of UNIT1.

Pinching together the white and green knobs (2 sets on 

• 

the right and left), lift the opposing pole plate up and 
remove it.

Ionised wire

Ionising frame

Pinching the sets of knobs 
on the right and left at the 
same time makes it easier 
to remove the opposing 
pole plate.

Be careful not to cut the 
internal ionised wires.

Opposing 
pole plates

Knob 
(green)

Knob 
(white)

Wear rubber 

gloves.

Attach

Attach the opposing pole plates.

Fit the opposing pole plate over the knobs (2 sets on the 

1) 

right and left) on the ionising frame.

The opposing pole plates have no difference between the 
upper and the lower, or between the right and the left. 
Attach them so that the arrow is visible.

Ionising frame

Opposing 
pole plates

Arrow

Knob 
(white)

Wear rubber 

gloves.

Insert securely until it clicks.

2) 

 

Attach the other opposing pole plate.

3) 

Attach UNIT1 and the front panel.

Page 17.

 

01_EN_3P276413-2C.indd   18

01_EN_3P276413-2C.indd   18

9/27/2011   1:20:43 PM

9/27/2011   1:20:43 PM

Summary of Contents for MC70LBFVM

Page 1: ...Air Purifier OPERATION MANUAL Floor Standing Wall hanging Type MODEL MC70LBFVM English 00_CV_3P276413 2C indd 1 00_CV_3P276413 2C indd 1 9 17 2011 9 39 03 AM 9 17 2011 9 39 03 AM...

Page 2: ...cle size is quickly caught Deodorising and decomposing odour in the air The streamer discharge decomposes absorbed odour The decomposition cycle that maintains deodorising capability Adsorption The de...

Page 3: ...rational issues You may smell an odour as a particle of ozone is generated The amount is negligible and does not harm your health CONTENTS Read before Operation Features 1 Safety Precautions 3 Name an...

Page 4: ...he base Incomplete connections may lead to electric shock or fire because of overheating Periodically clean the dust and other matter from the power plug with a dry cloth Insulation failure caused by...

Page 5: ...nit Pulling on the power supply cord may lead to fire or electric shock because of short circuits Before long periods of disuse disconnect the power plug from the electrical socket Degraded insulation...

Page 6: ...ets do not urinate on the unit or bite the power supply cord This may lead to electric shock or fire In the event of abuse by pets stop operation disconnect the power plug and consult your dealer Do n...

Page 7: ...lter container Front panel Ventilation fan Ionised wire rear Ionising frame Opposing pole plates Safety guard Unit display Page 7 Page 16 Page 16 Page 15 Streamer unit UNIT2 Page 20 gray Deodorising c...

Page 8: ...ng the front panel and UNIT1 2 Operation directly after reconnecting the power plug When the sensitivity of the air quality sensor is poor change the setting Page 22 The sensitivity of the air quality...

Page 9: ...ur level remains constant without intensifying or weakening the odour sensor may not detect even strong odours The odour sensor may not detect certain types of odours such as pet odours other than amm...

Page 10: ...attach the pleated filter before starting operation Remove the front panel 1 Push the 2 clips right and left and pull the front panel upward and remove it Push Clip 1 each on right and left Front pan...

Page 11: ...s fit the projections into the grooves 4 locations at the bottom of the main unit and press the deodorising catalyst unit into the main unit 2 Press the deodorising catalyst unit until you hear clicki...

Page 12: ...e cleaning the air during heating or cooling operation Keep TVs radios and stereos 2m or more away from the unit The effects of the power circuit inside the unit and cable may cause a distorted TV pic...

Page 13: ...a doctor immediately When discarding batteries cover the terminals of the batteries with tape If mixed with other metal or batteries heat explosion or combustion may occur The replacement target is a...

Page 14: ...ildproof lock by pressing again for about 2 seconds You can also release the childproof lock when you disconnect the power plug once and after 3 seconds or more reconnect the power plug To operate the...

Page 15: ...etting for the airflow rate returns to Auto fan Before cleaning make sure to stop operation and disconnect the power plug Auto fan operation The airflow rate is automatically selected from Quiet Low S...

Page 16: ...e case of heavy dirt wash the prefilter with a soft brush or neutral detergent and dry it well in the shade Dry the prefilter completely before using it because the UNIT1 lamp may light up if any wate...

Page 17: ...nt Do not wash with water If the unit is washed with water it will be deformed and become unusable If the main unit or the air inlet for the air quality odour sensor is clogged with dust use a vacuum...

Page 18: ...m of the main unit and press the deodorising catalyst unit into the main unit Handles Deodorising catalyst unit 1 Fit here 2 Press the deodorising catalyst unit until you hear clicking sound Attach UN...

Page 19: ...and left at the same time makes it easier to remove the opposing pole plate Be careful not to cut the internal ionised wires Opposing pole plates Knob green Knob white Wear rubber gloves Attach Attach...

Page 20: ...t with a piece of cloth soft brush etc Wear rubber gloves Cloth Cotton swab For details 1 Ionising frame 2 Ionised wire Wear rubber gloves Wipe Brush Cloth Rub Wear rubber gloves Rinse in running wate...

Page 21: ...are deformed deodorising capacity diminishes For details 3 Streamer unit Cloth Cotton swab Wear rubber gloves Wipe If detergent remains on UNIT1 or UNIT2 the UNIT1 and UNIT2 lamps do not go off after...

Page 22: ...lter The replacement interval for the pleated filter varies according to how the unit is used and where it is located The filter lamp lights up after about 2 years if the unit is used every day in a h...

Page 23: ...ration again from the beginning Airflow rate lamp Sensitivity To raise the sensitivity Select the Low airflow rate lamp Low High The sensor more readily reacts to dust To lower the sensitivity Select...

Page 24: ...with water Does the unit need to be replaced Answer No the deodorising catalyst unit can not be washed with water If the unit is washed with water it will be deformed and become unusable When you hav...

Page 25: ...large amount of odour generated when starting operation of the unit The odour level of the initial 1 minute is used as the standard for the sensitivity of the odour sensor Operate the unit with an inc...

Page 26: ...d filter is replaced Did you press the filter reset button for 5 seconds Even if the pleated filter is replaced unless you press the filter reset button for 5 seconds the filter lamp does not go off P...

Page 27: ...English 26 MEMO 01_EN_3P276413 2C indd 26 01_EN_3P276413 2C indd 26 9 27 2011 1 21 07 PM 9 27 2011 1 21 07 PM...

Page 28: ...7 3A MC70LBFVM DAIKIN INDUSTRIES LTD Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC DAIKIN TCF 018 E3 10 2010 KEMA Quality B V 82726 KRQ EMC98 4545 EN60335 2 65 Shinri Sada Manager Q...

Page 29: ...3P276413 2C M10B194B 1111 HT Two dimensional bar code is a code for manufacturing 00_CV_3P276413 2C indd 2 00_CV_3P276413 2C indd 2 9 17 2011 9 39 14 AM 9 17 2011 9 39 14 AM...

Reviews: