Installation Tips

Indoor Unit Installation (1)

1. Removing and installing front panel.

Removal method

Hook fingers on the panel protrusions on the left and right 

of the main body, and open until the panel stops. Slide the 
front panel sideways to disengage the rotating shaft. Then 
pull the front panel toward 
you to remove it.

Installation method

Align the tabs of the front panel with the grooves, and push 

all the way in. Then close slowly. Push the center of the 
lower surface of the panel firmly to engage the tabs.

2. Removing and installing front grille.

Removal method

1)Remove front panel to remove the air filter.
2)Remove the front grille. (2 screws)
3)Pull the lower part of the front grille toward you, then 

remove the front grille completely.
(There are 2 hooks on the upper part.)

3. How to set the different addresses.

When two indoor units are 
installed in one room, the 
two wireless remote 
controllers can be set for 
different addresses.

1) In the same way as when 

connecting to an HA system, 
remove the metal plate 
electrical wiring cover.

2) Cut the address jumper (JA).
3) Cut the address jumper (J4).

If it is difficult to remove, open the front grille and raise the 
top grid, using a screwdriver, to unhook the hooks.

1.

Installing the mounting plate.

• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and 

mark the boring points on the wall.

2) Secure the mounting plate to the wall with screws.

Recommended mounting-plate
retention spots and Dimensions

Installation method

1) Attach the front grille to the bottom frame, and lock the upper 

hooks (2 points) securely.

2) Install 2 screws of the front grill.
3) Install the air filter and then mount the front panel.

Push the 
rotating shaft of 
the front panel 
into the groove.

Address

J4

EXIST

1

 CUT

2

* The removed pipe port cover can be 
   kept in the mounting plate pocket.

Removed pipe 
port cover 

A

Mounting plate

Filter guide

Screwdriver

Upper grille

Raise and
remove

Hook

Screwdriver

Upper hook

JA

ADDRESS

ADDRESS:

CUT

EXIST

1

2

JA

JB
JC

Metal plate electrical
wiring cover

Sensor
parts cover

PCB

Electric
parts box

Claws (4 points)

Leveling mounting plate

(unit: inch (mm))

10-13/16 (273)

1-

5/8

(41.5)

2-1/16

(52)

2-3/8

(60)

4-1/8

(105)

2-9/16

(65)

3-3/8

(85)

4-11/16

(119)

3-11/16

(96)

30-7/8 (784)

Through-the-wall 
hole ø2-9/16 (ø65)

Drain hose position

Gas pipe end

Liquid pipe end

3-3/4

(95)

4-5/16

(110)

Unit outline

2

(51)

3-3/8

(85)

1-5/8

(41.5)

(Bolt size: 3/8 (M10))

Recommended 
mounting-plate 
retention spots 
(6 spots in all)

(Bolt size: 3/8 (M10))

Use tape measure 
as shown. 
Position the end of 
tape measure at    .

Dangle a weighted thread and 
align thread with vertical arrow.

a

Place a leveler 
on raised tab.

b

J4

Summary of Contents for M08B055

Page 1: ...or death WARNING Installation should be left to the authorized dealer or another trained professional Improper installation may cause water leakage electrical shock fire or equipment damage Install th...

Page 2: ...and builds up around the unit it may catch fire Establish drain piping according to the instructions of this manual Inadequate piping may cause water damage Tighten the flare nut according to the spec...

Page 3: ...m ceiling Front panel 1 15 16 50mm or more from walls on both sides B 3 16 1 L M4 25mm The mounting plate should be installed on a wall which can support the weight of the indoor unit A Mounting plate...

Page 4: ...talled on a wall which can support the weight of the indoor unit 1 Temporarily secure the mounting plate to the wall make sure that the panel is completely level and mark the boring points on the wall...

Page 5: ...the bottom edge of indoor unit with both hands until it is firmly caught by the mounting plate hooks Secure indoor unit to the mounting plate with the screws 3 16 1 2 L M4 12mm 2 Boring a wall hole an...

Page 6: ...h terminal numbers on indoor and outdoor unit s terminal blocks and firmly screw wires to the corresponding terminals 3 Connect the earth wires to the corresponding terminals 4 Pull wires to make sure...

Page 7: ...aterials When using commercial copper pipes and fittings observe the following 1 Insulation material Polyethylene foam Heat transfer rate 0 041 to 0 052 W mK 0 024 to 0 030 Btu fth F 0 035 to 0 045 kc...

Page 8: ...f the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again Test items Incomplete cooling heat...