Indoor Unit Installation (2)

3.

Installing indoor unit.

3-1. Right-side, right-back, or right-bottom piping.

1) Attach the drain hose to the underside of the refrigerant pipes 

with adhesive vinyl tape.

2) Wrap the refrigerant pipes and drain hose together with 

insulation tape.

3) Pass the drain hose and refrigerant pipes through the wall 

hole, then set the indoor unit on the mounting plate hooks by 
using the    markings at the top of the indoor unit as a guide.

4) Open the front panel, then open the service lid. (Rifer to 

Installation Tips.)

5) Pass the interconnecting wires from the outdoor unit through 

the feed-through wall hole and then through the back of the 
indoor unit. Pull them through the front side. 
Bend the ends of tie wires upward in advance for easier work. 
(If the interconnecting wire ends are to be stripped first, bundle 
wire ends with adhesive tape.)

6) Press the indoor unit’s bottom panel with both hands to set it 

on the mounting plate hooks. Make sure the wires do not catch 
on the edge of the indoor unit.

3-2. Left-side, left-back, or left-bottom piping.

1) Attach the drain hose to the underside of the refrigerant pipes 

with adhesive vinyl tape.

2) Be sure to connect the drain hose to the drain port in place of 

a drain plug.

3) Shape the refrigerant pipe along the pipe path 

marking on the mounting plate.

4) Pass drain hose and refrigerant pipes through 

the wall hole, then set the indoor unit on 
mounting plate hooks, using the    markings at 
the top of indoor unit as a guide.

5) Pull in the interconnecting wires.
6) Connect the inter-unit piping.
7) Wrap the refrigerant pipes and drain hose together with 

insulation tape as right figure, in case of setting the drain hose 
through the back of the indoor unit.

8) While exercising care so that the interconnecting wires do not catch 

indoor unit, press the bottom edge of indoor unit with both hands until 
it is firmly caught by the mounting plate hooks.  Secure indoor unit to 
the mounting plate with the screws (3/16” × 1/2”L (M4 × 12mm)).

2.

Boring a wall hole and installing wall embedded pipe.

• For walls containing metal frame or metal board, be sure to use a wall 

embedded pipe and wall cover in the feed-through hole to prevent 
possible heat, electrical shock, or fire.

• Be sure to caulk the gaps around the pipes with caulking material to 

prevent water leakage.

1) Bore a feed-through hole of 2-9/16 inch (65mm) in the wall so it has a 

down slope toward the outside.

2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe 

hole gap with putty.

Right-bottom 
piping

Right-back piping

Bind coolant pipe 
and drain hose 
together with 
insulating tape.

Remove pipe port cover 
here for right-side piping.

Remove pipe port cover 
here for right-bottom piping.

Inside

Outside

Caulking

Wall embedded pipe 
(Field supply)

Wall hole cover
(Field supply)

Wall embedded pipe 
(Field supply)

φ

2-9/16”

(

φ

65mm)

Mounting plate

A

Wire guide

When stripping the 
ends of interconnecting 
wires in advance, bind 
right ends of wires with 
insulating tape.

Hang indoor unit’s hook here.

Interconnecting
wires

Mounting plate

A

Remove pipe port cover here for left-bottom piping.

Remove pipe 
port cover 
here for left-
side piping.

Left-bottom piping

Left-side 
piping

Left-back 
piping

How to set drain plug

No gap

Do not apply lubricating 
oil (refrigerant machine 
oil) when inserting.
Application of causes 
deterioration and drain 
leakage of the plug.

Insert a hexagon wrench (3/16 inch (4mm))

Wrap insulating tape around the 
bent portion of refrigerant pipe. 
Overlap at least half the width 
of the tape with each turn.

Drain 
hose

Caulk this hole 
with putty or 
caulking material.

Bind with plastic 
tape.

 A Mounting plate

Refrigerant
pipes

Drain hose

Bottom frame

H  3/16” 

×

 1/2”L

(M4 

× 

12mm) (2 point)

Interconnecting wire

Mounting
plate

A

Summary of Contents for M08B055

Page 1: ...or death WARNING Installation should be left to the authorized dealer or another trained professional Improper installation may cause water leakage electrical shock fire or equipment damage Install th...

Page 2: ...and builds up around the unit it may catch fire Establish drain piping according to the instructions of this manual Inadequate piping may cause water damage Tighten the flare nut according to the spec...

Page 3: ...m ceiling Front panel 1 15 16 50mm or more from walls on both sides B 3 16 1 L M4 25mm The mounting plate should be installed on a wall which can support the weight of the indoor unit A Mounting plate...

Page 4: ...talled on a wall which can support the weight of the indoor unit 1 Temporarily secure the mounting plate to the wall make sure that the panel is completely level and mark the boring points on the wall...

Page 5: ...the bottom edge of indoor unit with both hands until it is firmly caught by the mounting plate hooks Secure indoor unit to the mounting plate with the screws 3 16 1 2 L M4 12mm 2 Boring a wall hole an...

Page 6: ...h terminal numbers on indoor and outdoor unit s terminal blocks and firmly screw wires to the corresponding terminals 3 Connect the earth wires to the corresponding terminals 4 Pull wires to make sure...

Page 7: ...aterials When using commercial copper pipes and fittings observe the following 1 Insulation material Polyethylene foam Heat transfer rate 0 041 to 0 052 W mK 0 024 to 0 030 Btu fth F 0 035 to 0 045 kc...

Page 8: ...f the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again Test items Incomplete cooling heat...

Reviews: