Safety Precautions

Accessories

Choosing a Site

1.

Indoor unit.

The indoor unit should be sited in a place  where:

1) the restrictions on installation specified in the indoor unit installation drawings are met,
2) both air intake and exhaust have clear paths met,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote controller range,
8) the unit is at least 3.5 ft (1m) away from any television or radio set (unit may cause interference with the picture or sound).

2.

Wireless remote controller.

1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are 

properly received by the indoor unit (within 23 ft (7m)).

• Before choosing the installation site, obtain user approval.

A

Mounting plate

E

Remote controller holder

K

Operation manual

L

Installation manual

D

Wireless remote controller

B

Mounting plate fixing screws 
3/16” × 1”L (M4 × 25mm)

F

Fixing screws for remote controller 
holder 1/8” × 13/16”L (M3 × 20mm)

C

Air-purifying filter with 
photocatalytic deodorizing function

G

Dry batteries AAA. LR03 (alkaline)

H

Indoor unit fixing screws
3/16” × 1/2”L (M4 × 12mm)

1

10

2

1

1

2

2

2

1

1

CAUTION

• Do not install the air conditioner where gas leakage would be exposed to open flames.  

If the gas leaks and builds up around the unit, it may catch fire.

• Establish drain piping according to the instructions of this manual.  

Inadequate piping may cause water damage.

• Tighten the flare nut according to the specified torque. A torque wrench should be used. 

If the flare nut is tightened too much, the flare nut may crack over time and cause refrigerant leakage. 

• Do not touch the heat exchanger fins. 

Improper handling may result in injury.

• Be very careful about product transportation. 

Some products use PP bands for packaging. Do not use any PP bands for a means of transportation. It is dangerous.

WARNING

• When installing or relocating the system, be sure to keep the refrigerant circuit free from all substances other than the specified refrigerant (R410A), such as air. 

(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise which may result in rupture, resulting in injury.)

• During pump-down, stop the compressor before removing the refrigerant piping. 

If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, 
causing abnormally high pressure which could lead to equipment damage or and personal injury.

• During installation, attach the refrigerant piping securely before running the compressor. 

If the compressor is not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, causing 
abnormally high pressure which could lead to equipment damage and personal injury.

• Be sure to install a ground fault circuit interrupter breaker. 

Failure to install a ground fault circuit interrupter breaker may result in electrically shocks, or fire personal injury.

Summary of Contents for M08B055

Page 1: ...or death WARNING Installation should be left to the authorized dealer or another trained professional Improper installation may cause water leakage electrical shock fire or equipment damage Install th...

Page 2: ...and builds up around the unit it may catch fire Establish drain piping according to the instructions of this manual Inadequate piping may cause water damage Tighten the flare nut according to the spec...

Page 3: ...m ceiling Front panel 1 15 16 50mm or more from walls on both sides B 3 16 1 L M4 25mm The mounting plate should be installed on a wall which can support the weight of the indoor unit A Mounting plate...

Page 4: ...talled on a wall which can support the weight of the indoor unit 1 Temporarily secure the mounting plate to the wall make sure that the panel is completely level and mark the boring points on the wall...

Page 5: ...the bottom edge of indoor unit with both hands until it is firmly caught by the mounting plate hooks Secure indoor unit to the mounting plate with the screws 3 16 1 2 L M4 12mm 2 Boring a wall hole an...

Page 6: ...h terminal numbers on indoor and outdoor unit s terminal blocks and firmly screw wires to the corresponding terminals 3 Connect the earth wires to the corresponding terminals 4 Pull wires to make sure...

Page 7: ...aterials When using commercial copper pipes and fittings observe the following 1 Insulation material Polyethylene foam Heat transfer rate 0 041 to 0 052 W mK 0 024 to 0 030 Btu fth F 0 035 to 0 045 kc...

Page 8: ...f the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again Test items Incomplete cooling heat...

Reviews: