background image

Indoor Unit Installation Drawings

Intelligent-eye Sensor

1) Do not hit or violently push the intelligent-eye sensor. This can lead to damage and malfunction.
2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor’s detection area.

CAUTION

Moving the sensor to the left

Moving the sensor to the right

Intelligent-eye 
sensor

15˚ 15˚

Adjusting the angle

1) Once installation of the indoor unit is complete, adjust the 

angle of the Intelligent-eye sensor to ensure the detection 
area properly covers the room. (Adjustable angle: 15˚ to 
right and left of center)

2) Gently push and slide the sensor to adjust the angle. Aim so 

that the sensor is pointing to the center of the room, or to 
the part of the room that is most frequently used.

3) After adjusting the angle, gently wipe the sensor with a clean cloth, being careful not to scratch the sensor.

Cut thermal insulation 
pipe to an appropriate 
length and wrap it with 
tape, making sure that 
no gap is left in the 
insulation pipe’s cut line.

Caulk 
pipe hole 
gap 
with putty. 

1-3/16” (30mm) or more from ceiling

Front panel

1-15/16” (50mm) or more from walls 
(on both sides)

B 3/16” × 1”L 

(M4 × 25mm)

The mounting plate 
should be installed 
on a wall which can 
support the weight 
of the indoor unit.

A Mounting plate

Air filters

Install Air-purifying filter with photocatalytic 
deodorizing function on air filter

 D  Wireless 
remote controller

 E  
Remote 
controller holder

Before screwing the remote 
controller holder to the 
wall, make sure that control 
signals are properly 
received by indoor unit.

1/8” × 13/16”L 
(M3 × 20mm)

F

Wrap the insulation pipe with 
the finishing tape from bottom 
to top.

A  Mounting 

plate

Clip

Mark (rear side)

Front grille

Bottom frame

 How to attach the indoor unit.

Hook the claws of the bottom 
frame to the mounting plate.
If the claws are difficult to hook, 
remove the front grille.

 How to remove the indoor unit.

Push up the marked area (at the 
lower part of the front grille) to 
release the claws. 
If it is difficult to release, remove 
the front grille.

Service lid

Opening service lid

Service lid is opening/closing type.

Opening method

1) Remove the screws on the 

service lid.

2) Slide the service lid leftward.
3) Rotate the service lid upward.

C  Air-purifying filter with photocatalytic 

deodorizing function

C

Air filter

Air-purifying filter 
with photocatalytic 
deodorizing 
function

Summary of Contents for M08B055

Page 1: ...or death WARNING Installation should be left to the authorized dealer or another trained professional Improper installation may cause water leakage electrical shock fire or equipment damage Install th...

Page 2: ...and builds up around the unit it may catch fire Establish drain piping according to the instructions of this manual Inadequate piping may cause water damage Tighten the flare nut according to the spec...

Page 3: ...m ceiling Front panel 1 15 16 50mm or more from walls on both sides B 3 16 1 L M4 25mm The mounting plate should be installed on a wall which can support the weight of the indoor unit A Mounting plate...

Page 4: ...talled on a wall which can support the weight of the indoor unit 1 Temporarily secure the mounting plate to the wall make sure that the panel is completely level and mark the boring points on the wall...

Page 5: ...the bottom edge of indoor unit with both hands until it is firmly caught by the mounting plate hooks Secure indoor unit to the mounting plate with the screws 3 16 1 2 L M4 12mm 2 Boring a wall hole an...

Page 6: ...h terminal numbers on indoor and outdoor unit s terminal blocks and firmly screw wires to the corresponding terminals 3 Connect the earth wires to the corresponding terminals 4 Pull wires to make sure...