Indoor Unit Installation (3)

1) Do not use spliced wires, strand wires, extension cords, or starburst connections, as they may cause overheating, 

electrical shock, or fire. Follow all Local, and State electrical codes.

2) Do not use locally purchased electrical parts inside the product. (Do not overload the circuit by adding drain pump 

or other electrical equipment to unit terminals.)  Doing so may cause electric shock or fire.

3) When carrying out wiring connection, take care not to pull at the conduit.

WARNING

5.

When connecting to an HA system.

1) Remove the front grille. (2 screws)
2) Remove the electrical 

wiring box. (3 screw)

3) Remove the metal plate 

electrical wiring cover. (4 tabs)

4) Remove the resin plastic 

electrical wiring cover. (2 tabs)

5) Attach the connection cord to the S21 connector and pull 

the harness out through the notched part in the figure.

6) Replace the electrical wiring cover as it was,  and pull the harness around, as shown in the figure.

6.

Drain piping.

1) Connect the drain hose, 

as described right.

2) Remove the air filters 

and pour some water 
into the drain pan to 
check the water flows 
smoothly.

 

3) When drain hose requires extension, obtain 

an extension hose commercially available.

Be sure to thermally insulate the indoor 
section of the extension hose.

4) When connecting a rigid polyvinyl chloride pipe 

(nominal diameter 1/2 inch (13mm)) directly to the drain 
hose attached to the indoor unit as with embedded 
piping work, use any commercially available drain 
socket (nominal diameter 1/2 inch (13mm)) as a joint.

4.

Wiring.

1) Strip wire ends. (9/16 inch (15mm))

2) Match wire colours with terminal numbers on 

indoor and outdoor unit’s terminal blocks and 
firmly screw wires to the corresponding 
terminals.

3) Connect the earth wires to the corresponding 

terminals.

4) Pull wires to make sure that they are securely 

latched up.

5) In case of connecting to an adapter system. 

Run the remote controller cable and attach the S21 connector as the 
illustration above.

6) Shape the wires so that the service lid fits securely, then close service lid.

3-3. Wall embedded piping.

Follow the instructions given under

1) Insert the drain hose to this depth so it won’t be 

pulled out of the drain pipe.

Left-side, left-back, or left-bottom piping

The drain hose should 
be inclined downward.

No trap is permitted.

Do not put the end 
of the hose in water.

Indoor unit 
drain hose

φ

11/16”

(

φ

18mm)

Extension drain hose

Heat insulation tube
(Field supply)

Drain hose supplied with 
the indoor unit

Commercially available drain socket 
(nominal diameter 1/2 inch (13mm))

Commercially available rigid 
polyvinyl chloride pipe
(nominal diameter 1/2 inch (13mm))

φ

11/16”

(

φ

18mm)

3
2
1

1 2 3

L

1

L

2

When wire length exceeds 
33ft (10m), use AWG14 wires.

Use AWG16 or AWG14 wire 
for the Interconnecting wires.

Outdoor unit

Indoor 
unit

Inner wall

Vinyl chloride 
drain pipe 
(VP-30)

Drain hose

1-15/16”
(50mm) 
or more

Insert drain hose 
to this depth so 
it won’t be pulled 
out of drain pipe.

Outer wall

Use the specified wire type.

Shape wires so that the service 
lid will fit securely.

Electrical component box

Terminal block

1

2

3

Conduit 
mounting 
plate

Conduit 

Lock nut

Back

6) Pull-around figure

Tab

Tab

HA cord

Notched part

Press

Tab

Tab

HA connector (S21)

Slide

Slide

Press

Press

Screws

Press

4) 5) Attach to the S21 

connector and take the 
harness out of the notched 
part on the mounting.

3) Remove the metal 

plate electrical 
wiring cover.

Summary of Contents for M08B055

Page 1: ...or death WARNING Installation should be left to the authorized dealer or another trained professional Improper installation may cause water leakage electrical shock fire or equipment damage Install th...

Page 2: ...and builds up around the unit it may catch fire Establish drain piping according to the instructions of this manual Inadequate piping may cause water damage Tighten the flare nut according to the spec...

Page 3: ...m ceiling Front panel 1 15 16 50mm or more from walls on both sides B 3 16 1 L M4 25mm The mounting plate should be installed on a wall which can support the weight of the indoor unit A Mounting plate...

Page 4: ...talled on a wall which can support the weight of the indoor unit 1 Temporarily secure the mounting plate to the wall make sure that the panel is completely level and mark the boring points on the wall...

Page 5: ...the bottom edge of indoor unit with both hands until it is firmly caught by the mounting plate hooks Secure indoor unit to the mounting plate with the screws 3 16 1 2 L M4 12mm 2 Boring a wall hole an...

Page 6: ...h terminal numbers on indoor and outdoor unit s terminal blocks and firmly screw wires to the corresponding terminals 3 Connect the earth wires to the corresponding terminals 4 Pull wires to make sure...

Page 7: ...aterials When using commercial copper pipes and fittings observe the following 1 Insulation material Polyethylene foam Heat transfer rate 0 041 to 0 052 W mK 0 024 to 0 030 Btu fth F 0 035 to 0 045 kc...

Page 8: ...f the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again Test items Incomplete cooling heat...

Reviews: