background image

Summary of Contents for MV-H09BIF

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ... the EU To prevent possible harm to the environment or human health from un controlled waste disposal recycle it responsibly to promote the sustainable reuse of mate rial resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for envi ronmental safe recycling This appliance is not intended...

Page 6: ...at if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related information used to indicate risk of property damage Indicates a hazard that would be assigned a signal word WARNING or CAUTION WARNING CAUTION DANGER NOTICE ...

Page 7: ...hose recommended by the manufacture Should repair be necessary contact your nea rest authorized Service Centre Any repairs carried out by unqualified personnel may be dangerous The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Appliance shall be installed o...

Page 8: ...ppliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not wash the air conditioner with water to avoid electric ...

Page 9: ...damage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill water on the remote controller otherwise the electric shock or damage Please contact dealer when you need to repair air conditioner Do not repair air conditioner by yourself It may cause object...

Page 10: ...bles before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly connect the live wire neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit break with suitable capacity please...

Page 11: ...onnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The air conditioner is the first class electric appliance It keep the interconnection cable away from the copper tube The temperature of refrige...

Page 12: ... air conditioner without plug an circuit break far away from animals or plants If it is unavoidable please add the fence for safety purpose Select a location which is out of reach for children and reachable after finishing installation For the air conditioner with plug the plug should be Indoor side DB WB Outdoor side DB WB Maximum cooling 32 23 43 26 Maximum heating 27 24 18 NOTICE Working temper...

Page 13: ...ferent from above graphics please refer to actual products remote control NOTICE Actual product may be different from above graphics please refer to actual products air inlet panel filter aux button horizontal louver air outlet Parts Name Indoor Unit ...

Page 14: ...del For some model For some model For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator G W R Power LED color indicator Green status ON Red status OFF Mode LED color indicator White W Cool Mode Red R Heat Mode Green ...

Page 15: ...re Set time X FAN function TIMER ON TIMER OFF Child lock Up down swing Left right swing Light Temp display type Set temp Outdoor ambient temp Indoor ambient temp Sleep mode Clock Heat mode Fan mode Dry mode Cool mode Auto mode Operation mode I feel Healthy mode Quiet WiFi This is a general remote controller Some models have this function while some do not Please refer to the actual models Set fan ...

Page 16: ... of WiFi or wired controller the indoor unit must has been controlled by standard remote controller under auto mode first and then the function of adjustable temperature under auto mode can be realized by APP or the wired controller This remote controller can adjust the temperature under auto mode When matching with the unit which is without the function of adjustable temperature under auto mode t...

Page 17: ...o Auto Having set X FAN function on After turning off the unit by pressing ON OFF button indoor fan will continue running for a few minutes at low speed In this period Hold fan speed button for 2s to stop indoor fan directly Having set X FAN function off After turning off the unit by pressing ON OFF button the complete unit will be off directly This function indicates that moisture on evaporator o...

Page 18: ...K press or button to adjust time Refer to CLOCK TIMER ON TIMER OFF buttons Introduction for buttons on remote controller The function is only available for some model Press this button continuously more than 2s the main unit will swing back an forth from left to right and then loosen the button the unit will stop swinging and present position of guide louver will be kept immediately Under swing le...

Page 19: ...will display the corresponding temperature of last setting sleep curve and blink 4 Repeat the above step 2 3 operation until 8 hours temperature setting finished sleep curve setting finished at this time the remote controller will resume the original timer display temperature display will resume to original setting temperature Sleep3 the sleep curve setting under Sleep mode by DIY could be inquire...

Page 20: ...n resumes displaying Cancel TIMER ON Under the condition that TIMER ON is started up press TIMER ON button to cancel it TIMER OFF button TIMER OFF button can set the time for timer off After pressing this button icon disappears and the word OFF on remote controller blinks Press or button to adjust TIMER OFF setting After each pressing or button TIMER OFF setting will increase or decrease 1min Hold...

Page 21: ...mode according to the comparison between indoor ambinet temperature and set temperature Under heating mode indoor fan operates at notch 3 speed or quiet mode according to the comparison between indoor ambient temperature and set temperature Under dry fan mode indoor fan operates at quiet mode Under auto mode the indoor fan operates at the auto quiet mode according to actual cooling heating or fan ...

Page 22: ...troller temperature indicator on indoor unit displays indoor ambient temperature When selecting with remote controller temperature indicator on indoor unit displays outdoor ambient temperature Note Outdoor temperature display is not available for some models At that time indoor unit receives signal while it displays indoor set temperature It s defaulted to display set temperature when turning on t...

Page 23: ...e press sleep button will cancel 8 heating function If sleep function has been set under cooling mode start up the 8 heating function will cancel sleep function Under temperature display the remote controller will display 46 heating 8 heating function Under heating mode press TEMP and CLOCK buttons simultaneously to start up or turn off 8 heating function When this function is started up and 8 wil...

Page 24: ...e position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall During operation point the remote control signal sender at the receiving window on indoor unit The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles between them Signal may be interfered easily in the...

Page 25: ...r conditioner The operation in details are as below 19 Clean and maintenance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use volatile liquid to clean the air conditioner Clean surface of indoor unit When the surface of indoor unit is dirty it is recommende...

Page 26: ...n panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly operation environment clean frequency can be increased WARNING 20 ...

Page 27: ...e pipe is damaged 1 Disconnect power supply 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air conditioner please contact local dealer or consultant service center for the correct disposal method ...

Page 28: ...nsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit Check the batteries If the power of batteries is too low please replace them Take the remote controller close to indoor unit and then try it again Check whether remote cont roller appears to be dama...

Page 29: ...r condit ioner can t operate Mist is em itted from indoor unit s air outlet Indoor temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper ature can t be adjusted Your required temperature exceeds the set temperature range Set temperature range 16 30 Cool...

Page 30: ...put back power and then turn on the unit again Water noise Air conditioner is turned on or turned off just now The noise is the sound of the unit which is a normal phenomenon Cracking noise Air conditioner is turned on or turned off just now This is the sound of friction caused by expansion and or contraction of panel or other parts due to the change of temperature Malfunction analysis Air conditi...

Page 31: ... off air conditioner and discon for service Power cord is overheating or damaged There s abnormal sound during operation Air switch trips off frequently Air conditioner gives off burning smell Indoor unit is leaking If the air conditioner operates under abnormal conditions it may cause Malfunction analysis Error Code When air conditioner status is abnormal temperature indicator on indoor unit will...

Page 32: ... area is well ventilated The continuous ventilation status should be kept during the operation process Check whether there is fire source or potential fire source in the maintenance area The naked flame is prohibited in the maintenance area and the no smoking warning board should be hanged nameplate Check whether the appliance mark is in good condition Replace the vague or damaged warning mark If ...

Page 33: ... pump and it s well ventilated Use the refrigerant filling appliances specialized for R32 Make sure that different kinds of refrigerant won t contaminate with each other After filling is finished please do the leakage detection before test running another time of leak detection should be done when it s removed Please use the flammable gas detector to check before unload and open the container No f...

Page 34: ...28 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm At least 15cm Space to the wall Space to the wall ...

Page 35: ...ry make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is not yet connected air will be sucked in and cause pressure rise or compressor rupture resulting in injury When installing the unit make sure that connection pipe is securely connected before the comp...

Page 36: ...ction If it is unavoidable please consult the local dealer 1 The place with strong heat sources vapors flammable or explosive gas or volatile objects spread in the air 2 The place with high frequency devices such as welding machine medical equipment as truck or in the corrosive environment such as chemical factory 3 The place near coast area 4 The place with oil or fumes in the air 5 The place wit...

Page 37: ...he interconnec tion cable away from the copper tube 9 10 Appliance shall be installed operated and stored in a room with a floor area Please notice that the unit is filled with flammable gas R32 Inappropriate larger than X m see table 1 treatment of the unit involves the risk of severe damages of people and material Details to this refrigerant are found in chapter refrigerant 2 The appliance shall...

Page 38: ...ion particles in the holes 3 Fix the wall mounting frame on the wall with tapping screws and 1 Choose the position of piping hole according to the direction of outlet pipe The position of piping hole should be a little lower than the wall mounted frame shown as below Step three open piping hole MV H18BIF Wall Left Wall Φ50mm Right Mark in the middle of it Level meter Rear piping hole Space to the ...

Page 39: ...ng out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left left rear left right rear right Step four outlet pipe Installation of indoor unit union nut pipe joint pipe Note Pay attention to dust prevention and take relevant safety measures when opening the ho...

Page 40: ...he indoor drain hose in order to prevent condensation The plastic expansion particles are 1 Open the panel remove the screw on the wiring cover and then take down the cover wiring cover screw panel Step seven connect wire of indoor unit 4 Wrap the indoor pipe and joint of con Installation of indoor unit torque wrench open end wrench indoor pipe pipe union nut Hex nut diameter Tightening torque N m...

Page 41: ...itch must be installed in the line The air switch should be all pole parting and the contact parting distance should be more than 3mm power connection wire cable cross hole 2 Make the power connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side 35 3 Remove the wire clip connect the power connection wire to the wiring terminal according t...

Page 42: ...eparately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with seal...

Page 43: ...ble malfunction The unit may drop shake or emit noise Have you done the refrigerant leakage test heating capacity It may cause condensation and water dripping Is water drained well It may cause condensation and water dripping Is the voltage of power supply accord ing to the voltage marked on the nameplate It may cause malfunction or damaging the parts Is electric wiring and pipeline installed corr...

Page 44: ...032W 7000Btu h 2051W 28000Btu h 8204W 9000Btu h 2637W 36000Btu h 10548W 12000Btu h 3516W 42000Btu h 12306W 18000Btu h 5274W 48000Btu h 14064W Max length of connection pipe Max length of connection pipe 15 25 15 30 15 30 20 30 25 30 2 Min length of connection pipe For the unit with standard connection pipe of 5m there is no limitation for the min length of connection pipe For the unit with standard...

Page 45: ... Diameter of connection pipe mm Liquid pipe Gas pipe Ф6 Ф6 or Ф9 5 Ф9 5 or Ф12 Ф12 Ф16 Ф19 Ф22 2 Ф16 or Ф19 Ф19 or Ф22 2 Ф25 4 or Ф31 8 _ _ Cooling only cooling and heating g m g m Cooling only g m cooling and heating 16 40 80 136 200 200 280 280 48 24 12 12 200 280 96 96 40 16 Indoor unit throttle Outdoor unit throttle Configuration of connection pipe ...

Page 46: ...rrs from getting into the pipe downwards pipe shaper C Put on suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander Note A is different according to the diameter please refer to the sheet below expander hard mold pipe F Inspection Check th...

Page 47: ......

Page 48: ......

Reviews: