14 Relocation

Installation and operation manual

30

4BY1

Air-cooled refrigeration condensing unit

4P495373-1 – 2017.07

▪ When  the  tone  of  operating  noise  changes.  This  noise  is  caused

by the change of frequency.

13.1.4

Symptom: Dust comes out of the unit

When  the  unit  is  used  for  the  first  time  in  a  long  time.  This  is
because dust has gotten into the unit.

13.1.5

Symptom: The outdoor unit fan does not
spin

During  operation.  The  speed  of  the  fan  is  controlled  in  order  to
optimise product operation.

14

Relocation

Contact  your  dealer  for  removing  and  reinstalling  the  total  unit.
Moving units requires technical expertise.

15

Disposal

This  unit  uses  hydrofluorocarbon.  Contact  your  dealer  when
discarding this unit.

NOTICE

Do not try to dismantle the system yourself: the dismantling
of  the  system,  treatment  of  the  refrigerant,  oil  and  other
parts  must  comply  with  applicable  legislation.  Units  must
be  treated  at  a  specialised  treatment  facility  for  reuse,
recycling and recovery.

Summary of Contents for LRMEQ3BY1

Page 1: ...Installation and operation manual Air cooled refrigeration condensing unit English Installation and operation manual Air cooled refrigeration condensing unit LRMEQ3BY1 LRMEQ4BY1...

Page 2: ...1700 1000 500 HU a b 100 100 c d e eB eD A B C D E HB HD A B C 200 300 1000 A B C E 200 300 1000 1000 500 D 1000 D E 1000 1000 500 B D HD HU 300 1000 HD HU 250 1500 HU HD HU 300 1500 B D E HB HD HB H...

Page 3: ...ktiver med senere ndringer Direktiv med f retagna ndringar Direktiver med foretatte endringer Direktiivej sellaisina kuin ne ovat muutettuina v platn m zn n Smjernice kako je izmijenjeno ir nyelv ek s...

Page 4: ...vastaava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplota...

Page 5: ...label 16 5 6 Connecting the electrical wiring 17 5 6 1 Field wiring Overview 17 5 6 2 Guidelines when knocking out knockout holes 18 5 6 3 Guidelines when connecting the electrical wiring 18 5 6 4 To...

Page 6: ...accessories from the outdoor unit 1 Remove the service cover See 5 1 1 To open the outdoor unit on page 9 2 Remove the accessories a 1 b 1 c 1 d 1 a 1 b 1 c 1 d 1 e 1 f 1 g 1 a General safety precaut...

Page 7: ...to top When the copper piping or fan is corroded When the heat exchanger is contaminated Foreign materials including oils for fabrication must be 30 mg 10 m Reuse allowed In other cases than above yo...

Page 8: ...e diameter of the outdoor unit stop valve 15 9 mm to that of the field piping 19 1 mm B C b c Piping between piping branching Use diameters depending on the total capacity of the indoor units connecte...

Page 9: ...The operation switch is located in the switchbox see illustration below R E M O T E OFF O N The operation switch can be set to the following three positions Operation switch setting Function OFF Unit...

Page 10: ...ng the paint field supply 4 Attach the cable s ends Tighten those ends 5 3 Connecting the refrigerant piping DANGER RISK OF BURNING 5 3 1 Using the stop valve and service port To handle the stop valve...

Page 11: ...w Check for refrigerant leaks after tightening the service port cover NOTICE Thread locking fluid Before reattaching the service port cover apply thread locking fluid to the screw thread NOT to the co...

Page 12: ...the unit without a dryer installed Possible consequence Equipment malfunction Install a dryer on the liquid piping Dryer type 80 g 100 molecular sieve equivalent DML083 DML083S Danfoss made Where how...

Page 13: ...example a to prevent snow and small animals from entering the system a WARNING Provide adequate measures to prevent that the unit can be used as a shelter by small animals Small animals that make con...

Page 14: ...ion of the system higher than the design pressure of the indoor unit 2 Test for leaks by applying a bubble test solution to all piping connections 3 Discharge all nitrogen gas NOTICE Make sure to use...

Page 15: ...e stop valve g Gas line stop valve A Valve A B Valve B C Valve C 2 Open valves B and C 3 Pre charge refrigerant until the determined additional refrigerant amount is reached or pre charging is not pos...

Page 16: ...to charge the unit even if the opening of the liquid line stop valve is adjusted If this is the case replace the cylinder with one that has more refrigerant remaining If the piping length is long repl...

Page 17: ...1M S1T Y1S Ry 0 S2T NC TeS1 No T1 T1 E1H t Ry0 t Ry 1 K1M S1T H1P P1 P2 W1 C C1 R X3M X1M L2 N L1 L3 B X2M A D C F1 F2 Ry 0 Ry 0 K1M Ry 0 Ry 0 Ry 0 K1M Ry 1 Y1S 3D111889 A e c a b i j k h f b d B B b...

Page 18: ...es when knocking out knockout holes NOTICE Precautions when making knockout holes Avoid damaging the casing After making the knockout holes we recommend you remove the burrs and paint the edges and ar...

Page 19: ...power supply is pulled loose from the stress relief NOTICE Never connect the power supply to terminal blocks X2M or X3M Otherwise the entire system may break down NOTICE Output signals The outdoor un...

Page 20: ...de 1 and 2 Mode Description Mode 1 monitoring settings Mode 1 can be used to monitor the current situation of the outdoor unit Some field setting contents can be monitored as well Mode 2 field setting...

Page 21: ...information See 6 1 7 Mode 1 and default situation Monitoring settings on page 21 Example 7 LEDs display Mode 1 See 8 1 1 To display the error codes of the latest malfunctions on page 24 6 1 6 To use...

Page 22: ...ating temperature during low noise operation With this setting the target evaporating temperature set with settings 2 0 and 2 1 can be corrected for low noise operation see setting 2 18 default 1 C 2...

Page 23: ...nsulation test of the main power circuit Using a megatester for 500 V check that the insulation resistance of 2 M or more is attained by applying a voltage of 500 V DC between power terminals and eart...

Page 24: ...ly completed normal operation is possible 7 3 3 Correcting after abnormal completion of the test run The test operation is only completed if no malfunction occurs In case of a malfunction perform corr...

Page 25: ...t the switch properly Replace defective component Outdoor fan motor signal failure Abnormal position of signal of 1 fan motor 4 Caution Abnormal fan motor signal circuit error Broken short or disconne...

Page 26: ...acle E in the direction of obstacle D HU Height of the unit HB HD Height of obstacles B and D 1 Seal the bottom of the installation frame to prevent discharged air from flowing back to the suction sid...

Page 27: ...microcurrent 1 mA 12 V DC For instructions on how to use the remote switch refer to the technical engineering data 7 The initial state of SW1 is open normal mode To activate low noise mode close the...

Page 28: ...result in injury Water pressure Check whether the water pressure is above 1 bar If it is lower add water 12 1 About the refrigerant This product contains fluorinated greenhouse gases Do NOT vent gase...

Page 29: ...make sure the air can flow freely Malfunction Measure The system operates but cooling is insufficient Check if air inlet or outlet of outdoor or indoor unit is not blocked by obstacles Remove any obs...

Page 30: ...it fan does not spin During operation The speed of the fan is controlled in order to optimise product operation 14 Relocation Contact your dealer for removing and reinstalling the total unit Moving un...

Page 31: ......

Page 32: ...4P495373 1 2017 07 Copyright 2016 Daikin 4P495373 1 0000000T...

Reviews: