(b) where corrosive gas, such as sulfurous acid gas, is pro-

duced
Corroding copper pipes or soldered parts may result in 
refrigerant leakage.

(c) near machinery emitting electromagnetic waves

Electromagnetic waves may disturb the operation of the 
control system and result in a malfunction of the equip-
ment.

(d) where flammable gases may leak, where there are car-

bon fiber or ignitable dust suspensions in the air, or 
where volatile flammables such as thinner or gasoline 
are handled.
Operating the unit in such conditions may result in 
fire.

2. BEFORE INSTALLATION

When moving the unit while removing it from the carton 
box, be sure to lift it by holding on to the four lifting lugs 
without exerting any pressure on other parts, especially, 
the refrigerant piping, drain piping, and other resin 
parts.

• Be sure to check the type of R410A refrigerant to be used 

before installing the unit. (Using an incorrect refrigerant will 
prevent normal operation of the unit.)

• The accessories needed for installation must be retained in 

your custody until the installation work is completed. Do not 
discard them!

• Decide upon a line of transport.
• Leave the unit inside its packaging while moving, until reach-

ing the installation site. Where unpacking is unavoidable, use 
a sling of soft material or protective plates together with a 
rope when lifting, to avoid damage or scratches to the unit.

• When selecting installation site, refer to the paper pattern.
• For the installation of an outdoor unit, refer to the installation 

manual attached to the outdoor unit.

• Do not install or operate the unit in rooms mentioned below.

Laden with mineral oil, or filled with oil vapor or spray 
like in kitchens. (Plastic parts may deteriorate which 
could eventually cause the unit to fall out of place, or 
could lead to leaks.)

Where corrosive gas like sulfurous gas exists. (Cop-
per tubing and brazed spots may corrode, which 
could eventually lead to refrigerant leaks.)

Where exposed to combustible gases and where vol-
atile flammable gas like thinner or gasoline is used. 
(Gas in the vicinity of the unit could ignite.)

Where machines can generate electromagnetic 
waves. (Control system may malfunction.)

Where the air contains high levels of salt such as that 
near the ocean and where voltage fluctuates greatly 
such as that in factories. 
Also in vehicles or vessels.

• This unit, both indoor and outdoor, is suitable for installation 

in a commercial and light industrial environment.
If installed as a household appliance it could cause electro-
magnetic interference.

2-1

PRECAUTIONS

• Be sure to read this manual before installing the indoor unit.
• Entrust installation to the place of purchase or a qualified ser-

viceman. Improper installation could lead to leaks and, in 
worse cases, electric shock of fire.

• Use only parts provided with the unit or parts satisfying 

required specifications. Unspecified parts could cause the 
unit to fall out of place, or could lead to leaks and, in worse 
cases, electric shock or fire.

2-2

ACCESSORIES

Check the following accessories are included with your 
unit.

2-3

OPTIONAL ACCESSORIES

• These are two types of remote controllers: wired and wire-

less. Select a remote controller according to customer 
request and install in an appropriate place.

NOTE

NOTE

NOTE

NOTE

• If the you wishes to use a remote controller that is not listed 

above, select a suitable remote controller after consulting 
catalogs and technical materials.

Name

(1) Drain hose

(2) Metal clamp 

Quantity

1 pc.

1 pc.

Shape

Name

(3) Washer for hanging 

bracket

(4) Clamp

Quantity

8 pcs.

6 pcs.

Shape

Name

(5) Paper pattern for 

installation

Insulation for fitting

Quantity

1 pc.

1 each

Shape

(6)For gas pipe

(7)For liquid pipe

Name

Sealing pad

(Other)

• Operation manual
• Installation manual

Quantity

1 each

Shape

(8) Large

(9) Small

Remote controller

Wired type

Wireless type

Heat pump type
Cooling only type

01_EN_3P172532-7.fm  Page 2  Thursday, December 15, 2005  2:45 PM

Summary of Contents for FXHQ32MVE

Page 1: ...E INSTALAR GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER ALGUNA DUDA PRIMA DELL INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFE...

Page 2: ...VE FXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1 FXAQ20MHV1 FXAQ25MHV1 FXAQ32MHV1 FXAQ40MHV1 FXAQ50MHV1 BEVQ50MVE FXLQ20MHV1 FXLQ25MHV1 FXLQ32MHV1 FXLQ40MHV1 FXLQ50MHV1 FXMQ40MAVE FXMQ50MAVE FXMQ63MAVE FXMQ80MA...

Page 3: ...lation work may result in the equipment falling and causing accidents Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried out by qual ified...

Page 4: ...ubing and brazed spots may corrode which could eventually lead to refrigerant leaks Where exposed to combustible gases and where vol atile flammable gas like thinner or gasoline is used Gas in the vic...

Page 5: ...wever if the ceiling is higher than 2 7m the remote control will have to be set locally Refer to 11 FIELD SETTING on page 12 3 Use suspension bolts for installation Check whether the ceiling is strong...

Page 6: ...on to remove Refer to Fig 5 Pull out of the accessories 3 Remove the hanger bracket Loosen two hanger bracket setting bolts M8 two on each side on each side for less than 10 mm Refer to Fig 6 and 7 Re...

Page 7: ...might cause leaks 6 REFRIGERANT PIPING WORK For refrigerant piping of outdoor units see the installation manual attached to the outdoor unit Execute heat insulation work completely on both sides of t...

Page 8: ...hen connecting or disconnecting pipes to from the unit Refer to Fig 16 Refer to Table1 for the dimensions of flare nut spaces When connecting the flare nut coat the flare section both inside and outsi...

Page 9: ...hose included with the main body Refer to Table 1 for tightening torque Table 1 Not recommendable but in case of emergency You must use a torque wrench but if you are obliged to install the unit witho...

Page 10: ...converging drain pipes whose gauge is suitable for the operating capacity of the unit 2 Confirm that smooth drainage is achieved after the pip ing work Add 0 6 liter of water in the drain pan from the...

Page 11: ...electric parts box lid Align the phase and connect the wire to the power terminal block 6P inside the electric parts box After connecting use the included clamps 4 to bind the wire together with the...

Page 12: ...smission wiring at least 50 mm away from power supply wiring The equipment may mal function if subjected to electrical external noise 5 For remote controller wiring refer to the INSTALLATION MANUAL OF...

Page 13: ...o perform wiring Connect input from outside to terminals T1 and T2 of the terminal block for remote controller 2 Actuation The following table explains FORCED OFF and ON OFF OPERATIONS in response to...

Page 14: ...in the field set mode select mode No 12 then set the first code switch No to 1 Then set second code position No to 01 for FORCED OFF and 02 for ON OFF OPERATION FORCED OFF at factory set 12 TEST OPER...

Page 15: ...0602 HT 3P172532 7 EM02A086B 00_CV_3P172532 7 fm Page 2 Tuesday December 13 2005 12 58 PM...

Reviews: