background image

1

English

FXHQ32AVEB
FXHQ63AVEB
FXHQ100AVEB

FXHQ32AVEB9
FXHQ63AVEB9
FXHQ100AVEB9

VRV SYSTEM Air Conditioners

Installation manual

CONTENTS

1. SAFETY PRECAUTIONS ................................................1

2. BEFORE INSTALLATION.................................................2

3. SELECTION OF INSTALLATION LOCATION ..................3

4. PREPARATION BEFORE INSTALLATION.......................4

5. INSTALLATION OF THE INDOOR UNIT .........................5

6. REFRIGERANT PIPING WORK ......................................6

7. DRAIN PIPING WORK.....................................................9

8. ELECTRIC WIRING WORK...........................................11

9. MOUNTING SUCTION GRILLE · DECORATION 

SIDE PANEL ..................................................................15

10. FIELD SETTING AND TEST OPERATION....................15

11. WIRING DIAGRAM ........................................................16

The original instructions are written in English. All other 
languages are translations of the original instructions.

1.

SAFETY PRECAUTIONS

Be sure to follow this “SAFETY PRECAUTIONS”. 
This product comes under the term “appliances not accessible 
to the general public”.
This is a class A product. In a domestic environment this 
product may cause radio interference in which case the user 
may be required to take adequate measures.

This manual classifies the precautions into WARNINGS and 
CAUTIONS.
Be sure to follow all the precautions below: They are all 
important for ensuring safety.

WARNING

 .................... Indicates a potentially hazard-

ous situation which, if not 
avoided, could result in death 
or serious injury.

CAUTION

 ..................... Indicates a potentially hazard-

ous situation which, if not 
avoided, may result in minor or 
moderate injury.
It may also be used to alert 
against unsafe practices.

After the installation is completed, test the air conditioner and 
check if the air conditioner operates properly.
Give the user adequate instructions concerning the use and 
cleaning of the indoor unit according to the Operation Manual.
Ask the user to keep this manual and the Operation Manual 
together in a handy place for future reference.

WARNING

• Ask your local dealer or qualified personnel to carry out 

installation work. 
Improper installation may result in water leakage, electric 
shocks or a fire.   

• Perform installation work in accordance with this installation 

manual.
Improper installation may result in water leakage, electric 
shocks or a fire.

• Consult your dealer regarding what to do in case of 

refrigerant leakage.
When the air conditioner is installed in a small room, it is 
necessary to take proper measures so that the amount of 
any leaked refrigerant does not exceed the concentration 
limit in the event of a leakage.
Otherwise, this may lead to an accident due to oxygen 
deficiency.

• Be sure to use only the specified parts and accessories for 

installation work.
Failure to use the specified parts may result in the air 
conditioner falling down, water leakage, electric shocks, a 
fire, etc.

• Install the air conditioner on a foundation that can withstand 

its mass.
Insufficient strength may result in the air conditioner falling 
down and causing injury.
In addition, it may lead to vibration of indoor units and cause 
unpleasant chattering noise. 

• Carry out the specified installation work in consideration of 

strong winds, typhoons, or earthquakes.
Improper installation may result in an accident such as air 
conditioner falling.

• Make certain that all electrical work is carried out by qualified 

personnel according to the applicable legislation (note 1) and 
this installation manual, using a separate circuit. 
In addition, even if the wiring is short, make sure to use a 
wiring that has sufficient length and never connect additional 
wiring to make the length sufficient.
Insufficient capacity of the power supply circuit or improper 
electrical construction may lead to electric shocks or a fire.
(note 1) applicable legislation means “All international, 

national and local directives, laws, regulations and/
or codes which are relevant and applicable for a cer-
tain product or domain”.

• Earth the air conditioner.

Do not connect the earth wiring to gas or water piping, 
lightning conductor or telephone earth wiring.
Incomplete earthing may cause electric shocks or a fire.

• Be sure to install an earth leakage breaker. 

Failure to do so may cause electric shocks and a fire.

• Disconnect the power supply before touching the electric 

components.
If you touch the live part, you may get an electric shocks.

• Make sure that all wiring is secure, using the specified 

wirings and ensuring that external forces do not act on the 
terminal connections or wirings. 
Incomplete connection or fixing may cause an overheat or a 
fire.

• When wiring between the indoor and outdoor units, and 

wiring the power supply, form the wirings orderly so that the 
control box lid can be securely fastened.
If the control box lid is not in place, overheat of the terminals, 
electric shocks or a fire may be caused.

• If refrigerant gas leaks during installation work, ventilate the 

area immediately. 
Toxic gas may be produced if refrigerant gas comes into 
contact with a fire.

• After completing the installation work, check to make sure 

that there is no leakage of refrigerant gas. 
Toxic gas may be produced if refrigerant gas leaks into the 
room and comes into contact with a source of a fire, such as 
a fan heater, stove or cooker. 

• Never directly touch any accidental leaking refrigerant. This 

could result in severe wounds caused by frostbite.

01_EN_3P368557-2D.fm  Page 1  Wednesday, February 13, 2019  2:46 PM

Summary of Contents for FXHQ32AVEB9

Page 1: ...ONSULTAS FUTURAS PRIMA DELL INSTALLAZIONE LEGGERE ATTENTAMENTE LE PRESENTI ISTRUZIONI CONSERVARE IL PRESENTE MANUALE IN UN LUOGO FACILMENTE ACCESSIBILE PER RIFERIMENTO FUTURO LEES DEZE INSTRUCTIES ZOG...

Page 2: ...parts may result in the air conditioner falling down water leakage electric shocks a fire etc Install the air conditioner on a foundation that can withstand its mass Insufficient strength may result...

Page 3: ...al attached to the outdoor unit Do not throw away the accessories until the installation work is completed After the indoor unit is carried into the room to avoid the indoor unit from getting damaged...

Page 4: ...d out Water leakage Does the drain flow out smoothly Water leakage Is the power supply volt age identical to that stated in the manufac turer s label on the air conditioner Does not operate burnout Ar...

Page 5: ...TION 1 For the locations of indoor unit hanging bolts piping outlet holes drain piping outlet hole and electric wiring inlet hole Refer to Fig 3 2 Make holes for hanging bolts piping outlet drain pip...

Page 6: ...Use M8 or M10 bolts for hanging the indoor unit Adjust the length of the hanging bolt from the ceiling in advance Refer to Fig 9 Use hole in anchors for the existing bolts and embedded inserts or foun...

Page 7: ...mass If the strength is insufficient the indoor unit may fall down and cause injuries 6 REFRIGERANT PIPING WORK For the outdoor unit refrigerant piping refer to the installation manual attached to th...

Page 8: ...ck securely that there is no gas leak If the nut is not tightened as instructed it may cause slow refrigerant leak and result in malfunction such as does not cool or heat Table 2 CAUTION Insulation of...

Page 9: ...eave clearance Wrap from the root of the indoor unit Sealing material Small 9 accessory Bring the seam to the top Flare nut connection Piping insulating material eld supply For prevention of sweating...

Page 10: ...left side refer to Fig 21 When conducting left rear left side drain piping remove the protection net Then remove the drain socket cap and insu lation material applied to left side drain socket and ap...

Page 11: ...nical document Connecting drain piping Do not connect the drain piping directly to the sewage that gives off ammonia odor The ammonia in the sewage may go through the drain piping and corrode the heat...

Page 12: ...the works are finished Carry out installation and wiring of the remote controller according to the installation manual attached to the remote controller Do not touch the Printed Circuit Board assembly...

Page 13: ...nnect the remote con troller wiring to P1 P2 and transmission wiring to F1 F2 no polarity Refer to Fig 32 Next tie into a bundle and fix by the included the wiring fixture 11 and clamp 4 so that no te...

Page 14: ...Remote controller wiring Clamp 4 accessory Power supply wiring and Earth wiring Wiring xture 11 accessory Screw for wiring xture 12 accessory Wiring xture 11 accessory Screw for wiring xture 12 acces...

Page 15: ...e remote controller 8 8 FOR REMOTE CONTROL FORCED OFF OR ON OFF OPERATION 1 Wiring method and specification Remote control is available by transmission the external input to the terminals T1 and T2 on...

Page 16: ...er with the operation manual Do not carry out setting other than those shown in the table 10 1 SETTING OF CEILING HEIGHT Set the SECOND CODE No according to the ceiling height as shown in the Table 3...

Page 17: ...est operation is completed before delivering the air conditioner to the customer confirm that the control box lid the air filter and suction panel are attached In addition explain the power supply sta...

Page 18: ...B SELECTOR SWITCH WIRELESS ADDRESS SET A2P A3P BS1 H1P H2P H3P H4P SS1 SS2 WIRING DIAGRAM CONNECTOR FOR OPTIONAL PARTS INDOOR UNIT 2 IN CASE USING CENTRAL REMOTE CONTROLLER CONNECT IT TO THE UNIT IN A...

Page 19: ...1904 HT 3P368557 2D EM12A009D 00_CV_3P368557 2D fm Page 2 Tuesday February 12 2019 10 56 AM...

Reviews: