7 Electrical installation

Installation manual

8

FTXTJ-A(W)(B)

Daikin room air conditioner

3P695637-3C – 2023.03

WARNING

If the supply cord is damaged, it MUST be replaced by the
manufacturer,  its  service  agent  or  similarly  qualified
persons in order to avoid a hazard.

WARNING

Do NOT connect the power supply to the indoor unit. This
could result in electrical shock or fire.

WARNING

▪ Do  NOT  use  locally  purchased  electrical  parts  inside

the product.

▪ Do  NOT  branch  the  power  supply  for  the  drain  pump,

etc.  from  the  terminal  block.  This  could  result  in
electrical shock or fire.

WARNING

Keep  the  interconnection  wiring  away  from  copper  pipes
without thermal insulation as such pipes will be very hot.

7.1

Specifications of standard wiring
components

NOTICE

We recommend using solid (single-core) wires. If stranded
wires are used, slightly twist the strands to consolidate the
end  of  the  conductor  for  either  direct  use  in  the  terminal
clamp  or  insertion  in  a  round  crimp-style  terminal.  Details
are described in "Guidelines when connecting the electrical
wiring" in the installer reference guide.

Component

Interconnection cable
(indoor↔outdoor)

Voltage

220~240 V

Wire size

Only use harmonized wire

providing double insulation

and suitable for applicable

voltage

4-core cable

1.5 mm²~2.5 mm

2

 (based on

outdoor unit)

7.2

To connect the electrical wiring to
the indoor unit

WARNING

Provide adequate measures to prevent that the unit can be
used  as  a  shelter  by  small  animals.  Small  animals  that
make contact with electrical parts can cause malfunctions,
smoke or fire.

NOTICE

▪ Keep  the  power  line  and  transmission  line  apart  from

each  other.  Transmission  wiring  and  power  supply
wiring may cross, but may NOT run parallel.

▪ In  order  to  avoid  any  electrical  interference,  the

distance  between  both  wirings  should  ALWAYS  be  at
least 50 mm.

Electrical  work  should  be  carried  out  in  accordance  with  the
installation manual and the national electrical wiring rules or code of
practice.

1

Set  the  indoor  unit  on  the  mounting  plate  hooks.  Use  the  " "
marks as a guide.

a

b

c

d

a

Mounting plate (accessory)

b

Piece of packing material

c

Interconnection cable

d

Wire guide

INFORMATION

Support the unit using a piece of packing material.

Example:

2

Open  the  front  panel,  and  then  the  service  cover.  Refer  to  the
Installer reference guide for opening procedure. For location of
the  installer  reference  guide  refer  to 

"1  About  the

documentation"

 [

4

 2].

3

Pass  the  interconnection  cable  from  the  outdoor  unit  through
the  feed-through  wall  hole,  through  the  back  of  the  indoor  unit
and through the front side.

Note: 

  In  case  the  interconnection  cable  was  stripped  in  advance,

cover the ends with insulating tape.

4

Bend the end of the cable up.

a
b

c

a

Terminal block

b

Electrical component block

c

Cable clamp

5

Strip the wire ends approximately 15 mm.

6

Match  wire  colours  with  terminal  numbers  on  the  indoor  unit
terminal blocks and firmly screw the wires to the corresponding
terminals.

7

Connect the earth wire to the corresponding terminal.

8

Firmly fix the wires with the terminal screws.

9

Pull  the  wires  to  make  sure  that  they  are  securely  attached,
then retain the wires with the wire retainer.

10

Shape  the  wires  so  that  the  service  cover  fits  securely,  then
close the service cover.

Summary of Contents for FTXTJ30A2V1BW

Page 1: ...Installation manual Daikin room air conditioner English Installation manual Daikin room air conditioner FTXTJ30A2V1BW FTXTJ30A2V1BB...

Page 2: ...olving problems based on error codes 11 12 Disposal 11 13 Technical data 12 13 1 Wiring diagram 12 13 1 1 Unified wiring diagram legend 12 1 About the documentation 1 1 About this document WARNING Mak...

Page 3: ...ST comply with the applicable legislation WARNING If the power supply has a missing or wrong N phase equipment might break down Establish proper earthing Do NOT earth the unit to a utility pipe surge...

Page 4: ...g persons using cardiac pacemakers or defibrillators This product may cause electromagnetic interference Auto control equipment E g automatic doors or fire alarm equipment This product may cause faul...

Page 5: ...a a a 605 mm a Recommended mounting plate fixing spots h Position for tape measure at symbol b Pocket for the pipe port cover i Drain hose c Use tape measure as shown j Liquid pipe d Tabs for placing...

Page 6: ...port cover here for right side piping b Remove the pipe port cover here for right bottom piping 5 3 2 To connect the piping on left side left back or left bottom INFORMATION The factory default is ri...

Page 7: ...on 6 2 Connecting the refrigerant piping DANGER RISK OF BURNING SCALDING 6 2 1 To connect the refrigerant piping to the indoor unit WARNING MILDLY FLAMMABLE MATERIAL The refrigerant inside this unit i...

Page 8: ...cause malfunctions smoke or fire NOTICE Keep the power line and transmission line apart from each other Transmission wiring and power supply wiring may cross but may NOT run parallel In order to avoid...

Page 9: ...as pipe e Drain pipe f Interconnection wire g Insulation tape h Vinyl tape 1 After the drain piping refrigerant piping and the electrical wiring are finished Wrap refrigerant piping interconnection ca...

Page 10: ...e sure drainage flows smoothly Possible consequence Condensate water might drip The system is properly earthed and the earth terminals are tightened The fuses or locally installed protection devices a...

Page 11: ...select channels of the indoor unit infrared receiver 11 Troubleshooting 11 1 Solving problems based on error codes Fault diagnosis by the wireless remote control If the unit runs into a problem you ca...

Page 12: ...E HA HE HL HN HR MR _A MR _B S U V W X A K R_ NE Connection connector D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Connector f...

Page 13: ...manual 13 FTXTJ A W B Daikin room air conditioner 3P695637 3C 2023 03 Symbol Meaning X Terminal X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C F...

Page 14: ......

Page 15: ......

Page 16: ...3P695637 3C 2023 03 Copyright 2023 Daikin Verantwortung f r Energie und Umwelt...

Reviews: