Installation manual

3

FTXTJ-A(W)(B)
Daikin room air conditioner
3P695637-3C – 2023.03

Unit installation (see 

"5 Unit installation"

 [

4

 4])

WARNING

Installation  shall  be  done  by  an  installer,  the  choice  of
materials  and  installation  shall  comply  with  the  applicable
legislation. In Europe, EN378 is the applicable standard.

WARNING

The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating  ignition  sources  (e.g.  open  flames,  an  operating
gas  appliance,  or  an  operating  electric  heater).  The  room
size shall be as specified in the General safety precaution.

CAUTION

For walls containing a metal frame or a metal board, use a
wall  embedded  pipe  and  wall  cover  in  the  feed-through
hole to prevent possible heat, electrical shock, or fire.

Piping installation (see 

"6 Piping installation"

 [

4

 7])

CAUTION

Piping  and  joints  of  a  split  system  shall  be  made  with
permanent  joints  when  inside  an  occupied  space  except
joints directly connecting the piping to the indoor units.

DANGER: RISK OF BURNING/SCALDING

CAUTION

▪ Incomplete flaring may cause refrigerant gas leakage.

▪ Do  NOT  re-use  flares.  Use  new  flares  to  prevent

refrigerant gas leakage.

▪ Use  flare  nuts  that  are  included  with  the  unit.  Using

different flare nuts may cause refrigerant gas leakage.

Electrical installation (see 

"7 Electrical installation"

 [

4

 7])

DANGER: RISK OF ELECTROCUTION

WARNING

ALWAYS use multicore cable for power supply cables.

WARNING

▪ All  wiring  MUST  be  performed  by  an  authorised

electrician  and  MUST  comply  with  the  applicable
national wiring regulation.

▪ Make electrical connections to the fixed wiring.

▪ All  components  procured  on-site  and  all  electrical

construction  MUST  comply  with  the  applicable
legislation.

WARNING

▪ If  the  power  supply  has  a  missing  or  wrong  N-phase,

equipment might break down.

▪ Establish  proper  earthing.  Do  NOT  earth  the  unit  to  a

utility  pipe,  surge  absorber,  or  telephone  earth.
Incomplete earthing may cause electrical shock.

▪ Install the required fuses or circuit breakers.

▪ Secure  the  electrical  wiring  with  cable  ties  so  that  the

cables  do  NOT  come  in  contact  with  sharp  edges  or
piping, particularly on the high-pressure side.

▪ Do  NOT  use  taped  wires,  extension  cords,  or

connections  from  a  star  system.  They  can  cause
overheating, electrical shock or fire.

▪ Do  NOT  install  a  phase  advancing  capacitor,  because

this  unit  is  equipped  with  an  inverter.  A  phase
advancing  capacitor  will  reduce  performance  and  may
cause accidents.

WARNING

Use  an  all-pole  disconnection  type  breaker  with  at  least
3  mm  between  the  contact  point  gaps  that  provides  full
disconnection under overvoltage category III.

WARNING

If the supply cord is damaged, it MUST be replaced by the
manufacturer,  its  service  agent  or  similarly  qualified
persons in order to avoid a hazard.

WARNING

Do NOT connect the power supply to the indoor unit. This
could result in electrical shock or fire.

WARNING

▪ Do  NOT  use  locally  purchased  electrical  parts  inside

the product.

▪ Do  NOT  branch  the  power  supply  for  the  drain  pump,

etc.  from  the  terminal  block.  This  could  result  in
electrical shock or fire.

WARNING

Keep  the  interconnection  wiring  away  from  copper  pipes
without thermal insulation as such pipes will be very hot.

3

About the box

3.1

Indoor unit

3.1.1

To remove the accessories from the
indoor unit

1

Remove:

▪ the accessory bag located at the bottom of the package,

▪ the mounting plate attached to the back of the indoor unit,

▪ the spare SSID sticker located on the front grille.

e

d

b

a

c

f

i

j

g

h

a

Installation manual

b

Operation manual

c

General safety precautions

Summary of Contents for FTXTJ30A2V1BW

Page 1: ...Installation manual Daikin room air conditioner English Installation manual Daikin room air conditioner FTXTJ30A2V1BW FTXTJ30A2V1BB...

Page 2: ...olving problems based on error codes 11 12 Disposal 11 13 Technical data 12 13 1 Wiring diagram 12 13 1 1 Unified wiring diagram legend 12 1 About the documentation 1 1 About this document WARNING Mak...

Page 3: ...ST comply with the applicable legislation WARNING If the power supply has a missing or wrong N phase equipment might break down Establish proper earthing Do NOT earth the unit to a utility pipe surge...

Page 4: ...g persons using cardiac pacemakers or defibrillators This product may cause electromagnetic interference Auto control equipment E g automatic doors or fire alarm equipment This product may cause faul...

Page 5: ...a a a 605 mm a Recommended mounting plate fixing spots h Position for tape measure at symbol b Pocket for the pipe port cover i Drain hose c Use tape measure as shown j Liquid pipe d Tabs for placing...

Page 6: ...port cover here for right side piping b Remove the pipe port cover here for right bottom piping 5 3 2 To connect the piping on left side left back or left bottom INFORMATION The factory default is ri...

Page 7: ...on 6 2 Connecting the refrigerant piping DANGER RISK OF BURNING SCALDING 6 2 1 To connect the refrigerant piping to the indoor unit WARNING MILDLY FLAMMABLE MATERIAL The refrigerant inside this unit i...

Page 8: ...cause malfunctions smoke or fire NOTICE Keep the power line and transmission line apart from each other Transmission wiring and power supply wiring may cross but may NOT run parallel In order to avoid...

Page 9: ...as pipe e Drain pipe f Interconnection wire g Insulation tape h Vinyl tape 1 After the drain piping refrigerant piping and the electrical wiring are finished Wrap refrigerant piping interconnection ca...

Page 10: ...e sure drainage flows smoothly Possible consequence Condensate water might drip The system is properly earthed and the earth terminals are tightened The fuses or locally installed protection devices a...

Page 11: ...select channels of the indoor unit infrared receiver 11 Troubleshooting 11 1 Solving problems based on error codes Fault diagnosis by the wireless remote control If the unit runs into a problem you ca...

Page 12: ...E HA HE HL HN HR MR _A MR _B S U V W X A K R_ NE Connection connector D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Connector f...

Page 13: ...manual 13 FTXTJ A W B Daikin room air conditioner 3P695637 3C 2023 03 Symbol Meaning X Terminal X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C F...

Page 14: ......

Page 15: ......

Page 16: ...3P695637 3C 2023 03 Copyright 2023 Daikin Verantwortung f r Energie und Umwelt...

Reviews: