background image

Table of Contents

Installation manual

2

FTXTJ-A(W)(B)

Daikin room air conditioner

3P695637-3C – 2023.03

Table of Contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 Specific installer safety instructions

2

3 About the box

3

3.1

Indoor unit .................................................................................

3

3.1.1

To remove the accessories from the indoor unit.........

3

4 About the unit

4

4.1

Operation range ........................................................................

4

4.2

About the wireless LAN .............................................................

4

4.2.1

Precautions when using the wireless LAN..................

4

4.2.2

Basic parameters ........................................................

4

5 Unit installation

4

5.1

Preparing the installation site ....................................................

4

5.1.1

Installation site requirements of the indoor unit ..........

4

5.2

Mounting the indoor unit............................................................

5

5.2.1

To install the mounting plate .......................................

5

5.2.2

To drill a wall hole .......................................................

5

5.2.3

To remove the pipe port cover ....................................

6

5.3

Connecting the drain piping.......................................................

6

5.3.1

To connect the piping on right side, right-back, or
right-bottom.................................................................

6

5.3.2

To connect the piping on left side, left-back, or left-
bottom .........................................................................

6

5.3.3

To check for water leaks .............................................

6

6 Piping installation

7

6.1

Preparing refrigerant piping .......................................................

7

6.1.1

Refrigerant piping requirements..................................

7

6.1.2

Refrigerant piping insulation .......................................

7

6.2

Connecting the refrigerant piping ..............................................

7

6.2.1

To connect the refrigerant piping to the indoor unit ....

7

6.2.2

To check refrigerant piping joints for leaks after
charging refrigerant.....................................................

7

7 Electrical installation

7

7.1

Specifications of standard wiring components ..........................

8

7.2

To connect the electrical wiring to the indoor unit .....................

8

7.3

To connect optional accessories (wired user interface, central
user interface, etc.)....................................................................

9

8 Finishing the indoor unit installation

9

8.1

To insulate the drain piping, refrigerant piping and
interconnection cable ................................................................

9

8.2

To pass the pipes through the wall hole....................................

9

8.3

To fix the unit on the mounting plate .........................................

10

9 Commissioning

10

9.1

Checklist before commissioning ................................................

10

9.2

To perform a test run .................................................................

10

9.2.1

To perform a test run using the wireless remote
control ......................................................................... 10

10 Configuration

11

11 Troubleshooting

11

11.1

Solving problems based on error codes....................................

11

12 Disposal

11

13 Technical data

12

13.1

Wiring diagram ..........................................................................

12

13.1.1

Unified wiring diagram legend..................................... 12

1

About the documentation

1.1

About this document

WARNING

Make  sure  installation,  servicing,  maintenance,  repair  and
applied  materials  follow  the  instructions  from  Daikin
(including  all  documents  listed  in  “Documentation  set”)
and, in addition, comply with applicable legislation and are
performed  by  qualified  persons  only.  In  Europe  and  areas
where  IEC  standards  apply,  EN/IEC  60335-2-40  is  the
applicable standard.

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

https://www.daikin.eu

.  Use  the  search

function   to find your model.

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

Scan the QR code below to find the full documentation set and more
information about your product on Daikin website.

FTXTJ-AB

FTXTJ-AW

The  original  instructions  are  written  in  English.  All  other  languages
are translations of the original instructions.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

Specific installer safety
instructions

Always observe the following safety instructions and regulations.

Summary of Contents for FTXTJ30A2V1BW

Page 1: ...Installation manual Daikin room air conditioner English Installation manual Daikin room air conditioner FTXTJ30A2V1BW FTXTJ30A2V1BB...

Page 2: ...olving problems based on error codes 11 12 Disposal 11 13 Technical data 12 13 1 Wiring diagram 12 13 1 1 Unified wiring diagram legend 12 1 About the documentation 1 1 About this document WARNING Mak...

Page 3: ...ST comply with the applicable legislation WARNING If the power supply has a missing or wrong N phase equipment might break down Establish proper earthing Do NOT earth the unit to a utility pipe surge...

Page 4: ...g persons using cardiac pacemakers or defibrillators This product may cause electromagnetic interference Auto control equipment E g automatic doors or fire alarm equipment This product may cause faul...

Page 5: ...a a a 605 mm a Recommended mounting plate fixing spots h Position for tape measure at symbol b Pocket for the pipe port cover i Drain hose c Use tape measure as shown j Liquid pipe d Tabs for placing...

Page 6: ...port cover here for right side piping b Remove the pipe port cover here for right bottom piping 5 3 2 To connect the piping on left side left back or left bottom INFORMATION The factory default is ri...

Page 7: ...on 6 2 Connecting the refrigerant piping DANGER RISK OF BURNING SCALDING 6 2 1 To connect the refrigerant piping to the indoor unit WARNING MILDLY FLAMMABLE MATERIAL The refrigerant inside this unit i...

Page 8: ...cause malfunctions smoke or fire NOTICE Keep the power line and transmission line apart from each other Transmission wiring and power supply wiring may cross but may NOT run parallel In order to avoid...

Page 9: ...as pipe e Drain pipe f Interconnection wire g Insulation tape h Vinyl tape 1 After the drain piping refrigerant piping and the electrical wiring are finished Wrap refrigerant piping interconnection ca...

Page 10: ...e sure drainage flows smoothly Possible consequence Condensate water might drip The system is properly earthed and the earth terminals are tightened The fuses or locally installed protection devices a...

Page 11: ...select channels of the indoor unit infrared receiver 11 Troubleshooting 11 1 Solving problems based on error codes Fault diagnosis by the wireless remote control If the unit runs into a problem you ca...

Page 12: ...E HA HE HL HN HR MR _A MR _B S U V W X A K R_ NE Connection connector D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Connector f...

Page 13: ...manual 13 FTXTJ A W B Daikin room air conditioner 3P695637 3C 2023 03 Symbol Meaning X Terminal X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C F...

Page 14: ......

Page 15: ......

Page 16: ...3P695637 3C 2023 03 Copyright 2023 Daikin Verantwortung f r Energie und Umwelt...

Reviews: