4 About the unit

Installation manual

4

FTXTJ-A(W)(B)

Daikin room air conditioner

3P695637-3C – 2023.03

d

Titanium apatite deodorising filter and silver particle filter
(Ag-ion filter)

e

Indoor unit fixing screw (M4×12L). Refer to 

"8.3 To fix the

unit on the mounting plate"

 [

4

 10].

f

Dry battery AAA.LR03 (alkaline) for the wireless remote
control

g

Wireless remote control with holder

h

Mounting plate (attached on the unit)

i

Screw cover

j

Spare SSID sticker with release paper (attached to the
unit)

Spare SSID sticker. 

Do NOT throw away the spare sticker. Keep

it  in  a  safe  place  in  case  it  is  needed  in  future  (e.g.  in  case  the
front grille was replaced attach it to the new front grille).

4

About the unit

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

4.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.

Cooling and

drying

(a)(b)

Heating

(a)

Outdoor temperature

–10~46°C DB

–30~24°C DB

–31~18°C WB

Indoor temperature

18~37°C DB

14~28°C WB

10~30°C DB

Indoor humidity

≤80%

(a)

(a)

A safety device might stop the operation of the system if the unit
runs outside its operation range.

(b)

Condensation and water dripping might occur if the unit runs
outside its operation range.

4.2

About the wireless LAN

For detailed specifications, installation instructions, setting methods,
FAQ, declaration of conformity and the latest version of this manual,
visit 

app.daikineurope.com

.

INFORMATION: Declaration of conformity

▪ Daikin  Industries  Czech  Republic  s.r.o.  declares  that

the  radio  equipment  type  inside  of  this  unit  is  in
compliance 

with 

Directive 

2014/53/EU 

and

S.I. 2017/1206: Radio Equipment Regulations 2017.

▪ This  unit  is  considered  as  combined  equipment

according to the definition of Directive 2014/53/EU and
S.I. 2017/1206: Radio Equipment Regulations 2017.

4.2.1

Precautions when using the wireless LAN

Do NOT use near:

Medical  equipment.

  E.g.  persons  using  cardiac  pacemakers  or

defibrillators. 

This 

product 

may 

cause 

electromagnetic

interference.

Auto-control  equipment.

  E.g.  automatic  doors  or  fire  alarm

equipment.  This  product  may  cause  faulty  behaviour  of  the
equipment.

Microwave oven.

 It may affect wireless LAN communications.

4.2.2

Basic parameters

What

Value

Frequency range

2400 MHz~2483.5 MHz

Radio protocol

IEEE 802.11b/g/n

Radio frequency channel

1~13

Output power

13 dBm

Effective radiated power

15 dBm (11b) / 14 dBm (11g) /
14 dBm (11n)

Power supply

DC 14 V / 100 mA

5

Unit installation

INFORMATION

If  you  are  not  sure  how  to  open  or  close  parts  of  the  unit
(front panel, electrical wiring box, front grille…) refer to the
installer reference guide of the unit for opening and closing
procedures.  For  location  of  the  installer  reference  guide
see 

"1.1 About this document"

 [

4

 2].

WARNING

Installation  shall  be  done  by  an  installer,  the  choice  of
materials  and  installation  shall  comply  with  the  applicable
legislation. In Europe, EN378 is the applicable standard.

5.1

Preparing the installation site

WARNING

The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating  ignition  sources  (e.g.  open  flames,  an  operating
gas  appliance,  or  an  operating  electric  heater).  The  room
size shall be as specified in the General safety precaution.

5.1.1

Installation site requirements of the
indoor unit

INFORMATION

The sound pressure level is less than 70 dBA.

Air flow.

 Make sure nothing blocks the air flow.

Drainage.

  Make  sure  condensation  water  can  be  evacuated

properly.

Wall insulation

. When conditions in the wall exceed 30°C and a

relative  humidity  of  80%,  or  when  fresh  air  is  inducted  into  the
wall,  then  additional  insulation  is  required  (minimum  10  mm
thickness, polyethylene foam).

Wall  strength. 

Check  whether  the  wall  or  the  floor  is  strong

enough to support the weight of the unit. If there is a risk, reinforce
the wall or the floor before installing the unit.

Spacing. 

Install the unit at least 1.8 m from the floor and keep the

following  requirements  in  mind  for  distances  from  the  walls  and
the ceiling:

Summary of Contents for FTXTJ30A2V1BW

Page 1: ...Installation manual Daikin room air conditioner English Installation manual Daikin room air conditioner FTXTJ30A2V1BW FTXTJ30A2V1BB...

Page 2: ...olving problems based on error codes 11 12 Disposal 11 13 Technical data 12 13 1 Wiring diagram 12 13 1 1 Unified wiring diagram legend 12 1 About the documentation 1 1 About this document WARNING Mak...

Page 3: ...ST comply with the applicable legislation WARNING If the power supply has a missing or wrong N phase equipment might break down Establish proper earthing Do NOT earth the unit to a utility pipe surge...

Page 4: ...g persons using cardiac pacemakers or defibrillators This product may cause electromagnetic interference Auto control equipment E g automatic doors or fire alarm equipment This product may cause faul...

Page 5: ...a a a 605 mm a Recommended mounting plate fixing spots h Position for tape measure at symbol b Pocket for the pipe port cover i Drain hose c Use tape measure as shown j Liquid pipe d Tabs for placing...

Page 6: ...port cover here for right side piping b Remove the pipe port cover here for right bottom piping 5 3 2 To connect the piping on left side left back or left bottom INFORMATION The factory default is ri...

Page 7: ...on 6 2 Connecting the refrigerant piping DANGER RISK OF BURNING SCALDING 6 2 1 To connect the refrigerant piping to the indoor unit WARNING MILDLY FLAMMABLE MATERIAL The refrigerant inside this unit i...

Page 8: ...cause malfunctions smoke or fire NOTICE Keep the power line and transmission line apart from each other Transmission wiring and power supply wiring may cross but may NOT run parallel In order to avoid...

Page 9: ...as pipe e Drain pipe f Interconnection wire g Insulation tape h Vinyl tape 1 After the drain piping refrigerant piping and the electrical wiring are finished Wrap refrigerant piping interconnection ca...

Page 10: ...e sure drainage flows smoothly Possible consequence Condensate water might drip The system is properly earthed and the earth terminals are tightened The fuses or locally installed protection devices a...

Page 11: ...select channels of the indoor unit infrared receiver 11 Troubleshooting 11 1 Solving problems based on error codes Fault diagnosis by the wireless remote control If the unit runs into a problem you ca...

Page 12: ...E HA HE HL HN HR MR _A MR _B S U V W X A K R_ NE Connection connector D V D Diode DB Diode bridge DS DIP switch E H Heater FU F U for characteristics refer to PCB inside your unit Fuse FG Connector f...

Page 13: ...manual 13 FTXTJ A W B Daikin room air conditioner 3P695637 3C 2023 03 Symbol Meaning X Terminal X M Terminal strip block Y E Electronic expansion valve coil Y R Y S Reversing solenoid valve coil Z C F...

Page 14: ......

Page 15: ......

Page 16: ...3P695637 3C 2023 03 Copyright 2023 Daikin Verantwortung f r Energie und Umwelt...

Reviews: