Outdoor Unit
SiUS091133
23
Printed Circuit Board Connector Wiring Diagram
2.2
RXS15/18LVJU
Connectors and
Other Parts
PCB (1): Filter PCB
PCB (2): Main PCB
1) S11
Connector for [S10] on main PCB
2) HL1, HN1, S
Connector for terminal board
3) E1, E2
Terminal for ground wire
4) HL2, HN2
Connector for [HL3] [HN3] on main PCB
5) HL4, HN4
Connector for [S12] on main PCB
6) FU1
Fuse (3.15 A, 250 V)
7) FU3
Fuse (30 A, 250 V)
8) V2, V3
Varistor
9) SW1
Forced cooling operation [ON/OFF] button
1) S10
Connector for [S11] on filter PCB
2) S12
Connector for [HL4] [HN4] on filter PCB
3) S20
Connector for electronic expansion valve coil
4) S40
Connector for overload protector
5) S70
Connector for fan motor
6) S80
Connector for four-way valve coil
7) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
8) HL3, HN3
Connector for [HL2] [HN2] on filter PCB
9) U, V, W
Terminal for compressor
10) FU2
Fuse (3.15 A, 250 V)
11) LED A
LED for service monitor (green)
12) V1
Varistor
13) J6
Jumper for facility setting