SiUS091133
Field Settings
Trial Operation and Field Settings
388
4.3
When 2 Units are Installed in 1 Room
Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding wireless
remote controller can be set for different addresses.
Both the indoor unit PCB and the wireless remote controller need alteration.
Indoor Unit PCB
Cut the address setting jumper JA on the control PCB.
Wireless Remote
Controller
Cut the address setting jumper.
FTXS09/12LVJU
FTXS15/18/24/30/36LVJU
FDXS series
ADDRESS
JC
JA
JB
ADDRESS:JA
EXIST
1
CUT
2
(R9665)
JA
ADDRESS
ADDRESS
JC
JA
JB
ADDRESS:JA
EXIST
1
CUT
2
ADDRESS: JA
CUT
EXIST
1
2
ADDRESS
JA
JC
JB
(R16921)
(R13525)
ADDRESS
EXIST
CUT
1
2
Jumper