SiUS091133
Indoor Unit: FTXS30/36LVJU
Removal Procedure
236
2. Remove the
INTELLIGENT EYE
sensor PCB.
1
Unfasten the 2 hooks
on the right and then
the 2 hooks on the left.
Remove the
INTELLIGENT EYE
sensor ASSY.
2
Remove the sensor
from the shield plate.
When reassembling, set the
sensor at the position where it
“clicks”. Otherwise, the sensor is
not completely set.
Step
Procedure
Points
(R9523)
Hook
Hook
INTELLIGENT EYE
sensor ASSY
(R9524)
(R9525)
Sensor
Shield plate