Main Functions
Function and Control
30
Frequency Limits
The following functions regulate the minimum and maximum frequency:
Forced Cooling
Operation
1.3
Airflow Direction Control (FTXS Series)
Power-Airflow
Dual Louvers
The large louver sends a large volume of air downward to the floor and provides an optimum
control in cooling, dry, and heating operation.
<Cooling / Dry>
During cooling or dry operation, the louver retracts into the indoor unit. Then, cool air can be blown
far and distributed all over the room.
<Heating>
During heating operation, the large louver directs airflow downward to spread the warm air to the
entire room.
Wide-Angle Fins
The fins, made of elastic synthetic resin, provide a wide range of airflow that guarantees
comfortable air distribution.
Auto-Swing
The following table explains the auto swing process for cooling, dry, heating, and fan:
Frequency
Functions
Low
Four-way
valve operation compensation. Refer to page 45.
High
Compressor protection function. Refer to page 46.
Discharge pipe temperature control. Refer to page 46.
Input current control. Refer to page 47.
Freeze-up protection control. Refer to page 48.
Heating peak-cut control. Refer to page 48.
Defrost control. Refer to page 50.
Vertical Swing (up and down)
Horizontal Swing
(right and left)
Cooling / Dry
Heating
Fan
09/12 class
15/18/24/30/36
class
15˚
45˚
35˚
55˚
(R13527)
30˚
70˚
30˚
65˚
(R11402)
5˚
80˚
30˚
65˚
(R11403)
45˚
45˚
(R11404)
(R9303)
60
°
50
°
25
°
15
°
(R9304)
70
°
40
°
75
°
30
°
(R9305)
75
°
15
°
25
°
70
°
(R9306)
45
°
45
°