Outdoor Unit: RKS30/36LVJU, RXS30/36LVJU
SiUS091133
371
Removal Procedure
7.3
Removal of PCBs
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the cover.
Preparation
Remove the electrical box
according to the “Removal of
Electrical Box”.
2
Disconnect the
connectors [S52]
[S102] from the service
monitor PCB.
3
Detach the 4 clamps
with pliers and remove
the service monitor
PCB.
Cover
(R9611)
Service monitor PCB
[S52]
[S102]
(R16707)
Clamp
(R16708)