Service Diagnosis
SiUS042113E
86
Part 6 Service Diagnosis
Notes
3. Service Diagnosis
3.1 Method 1
1. When
Timer Cancel
button is held down for 5 seconds,
00
is displayed on the temperature
display screen.
2. Press
Timer Cancel
button repeatedly until a long beep sounds.
1. A short beep or two consecutive beeps indicate non-corresponding codes.
2. To return to the normal mode, hold
Timer Cancel
button down for 5 seconds. When the remote
controller is left untouched for 60 seconds, it also returns to the normal mode.
3. Not all the error codes are displayed. When you cannot find the error code, try method 2.
Refer to page 87.
The code indication changes in the sequence shown below.
ARC466A70, A71
(R24045)
< ARC466 Series >
Timer Cancel
b
u
tton
No.
Code
No.
Code
No.
Code
No.
Code
No.
Code
1
00
10
E6
19
C9
28
A1
37
EA
2
A5
11
H6
20
CC
29
E1
38
AH
3
E7
12
H0
21
C4
30
UA
39
FA
4
F3
13
A6
22
C5
31
U3
40
E8
5
F6
14
U0
23
CH
32
UF
41
E3
6
L3
15
C7
24
J3
33
UH
42
H3
7
L4
16
A3
25
J6
34
P4
43
F8
8
L5
17
H8
26
J8
35
H7
44
A0
9
U4
18
H9
27
E5
36
U2
—
—
Summary of Contents for FTXM-V Series
Page 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Page 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Page 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Page 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Page 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...