SiUS042113E
Main Functions
Part 4 Functions and Control
35
1.9 NIGHT SET Mode
Outline
When the OFF TIMER is set, NIGHT SET mode is automatically activated. NIGHT SET mode
keeps the airflow rate setting.
Details
NIGHT SET mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers the target
temperature slightly in the case of heating. This prevents excessive cooling in summer and
excessive heating in winter to ensure comfortable sleeping conditions, and also conserves
electricity.
Cooling
Heating
1.10 ECONO Operation
Outline
ECONO operation reduces the maximum operating current and the power consumption.
This operation is particularly convenient for energy-saving. It is also a major bonus when breaker
capacity does not allow the use of multiple electrical devices and air conditioners.
It can be easily activated by pressing
Econo/Quiet
button on the wireless remote controller.
Details
When this function is activated, the maximum capacity also decreases.
The remote controller can send the ECONO command when the unit is in cooling, heating, dry,
or automatic operation. This function can only be set when the unit is running. To cancel the
ECONO operation, press
Econo/Quiet
button several times until the ECONO symbol
disappears.
This function and POWERFUL operation cannot be used at the same time. The latest command
has the priority.
(R23917)
Target temperat
u
re
+0.5°C (+0.9°F)
temperat
u
re shift
Operation stops
at the set ho
u
r
0.5°C (0.9°F)
1 ho
u
r
TIMER operation
NIGHT SET Mode ON
Target temperat
u
re
–2°C (–3.6°F)
temperat
u
re shift
1 ho
u
r
2°C (3.6°F)
(R23918)
TIMER operation
NIGHT SET Mode ON
ECONO operation
(R22012)
Normal operation
Maxim
u
m d
u
ring normal operation
Maxim
u
m d
u
ring ECONO operation
Time
Power
cons
u
mption
and c
u
rrent
Summary of Contents for FTXM-V Series
Page 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Page 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Page 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Page 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Page 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...