Notes on INTELLIGENT EYE operation
Application range is as follows.
If the air conditioner is in INTELLIGENT EYE operation and the mode “Do not blow directly on
people” is selected, the louvers adjust the airflow direction if there are people in the sensing
areas of the INTELLIGENT EYE so that the leftward or rightward airflow will not be directed to
the people. If no people are detected in either area 1 or 2 for 20 minutes, the air conditioner
switches to the energy-saving mode with the set temperature shifted by 3.6°F (2.0°C). The air
conditioner may switch to the energy-saving operation even if there are people in the areas.
This may occur depending on the clothes the people are wearing, if there is no movement of the
people in the areas.
The airflow direction from the louvers will be leftward if there are people in both areas 1 and 2.
The air will also flow left if there is a person right in front of the sensor as the sensor judges that
there are people in both areas.
Due to the position of the sensor, people might be exposed to the airflow of the indoor unit if
they are close to the front side of the indoor unit. If there are people close to the front side of the
indoor unit or in both areas, it is recommended to use the COMFORT AIRFLOW and
INTELLIGENT EYE operations simultaneously. Using both modes together, the air conditioner
will not direct the airflow towards the people.
The sensor could also mistakenly detect pets, sunlight, fluttering curtains and light reflected off
of mirrors as passers-by.
The sensor may not detect moving objects further than 23ft (7m) away. (Please see the
application range)
Sensor detection sensitivity changes according to the indoor unit location, the speed of
passers-by, temperature range, etc.
NIGHT SET mode will not switch on during use of INTELLIGENT EYE operation.
90°
55°
23ft (7m)
55°
Vertical angle 90°
(Side view)
Horizontal
angle 110°
(Top view)
23ft (7m)
Summary of Contents for FTXM-V Series
Page 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Page 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Page 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Page 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Page 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...