![background image](http://html1.mh-extra.com/html/daikin/ftk25jv1nb9/ftk25jv1nb9_service-manual_2459333137.webp)
For RK25J, RK35J, RX25J, RX35J
Si04-115
128
Removal Procedure
2.5
Removal of Compressor Noise Absorption Pad
Procedure
Warning Be sure to turn off all power supplies at least 10 min. before
disassembling work.
Step
Procedure
Points
1. To remove the right side
plate.
1
Remove the three
screws for removing the
right side plate.
2
Lift the right side plate
to disengage the hooks.
"
Insert the three hooks for the
restoration.
2. To remove the noise
absorber
"
Since the slit prepared for
the piping connection on the
noise absorption pad is torn
easily, remove the pad
carefully.
"
When restoring, the noise
absorption pad should pass
the internal side of the
piping.
1
Untie the string fixing
the body of the
compressor noise
absorption pad.