![Daikin FTK25JV1NB9 Service Manual Download Page 80](http://html1.mh-extra.com/html/daikin/ftk25jv1nb9/ftk25jv1nb9_service-manual_2459333080.webp)
Si04-115
Trouble shooting
Service Diagnosis
71
5.6
Faulty Indoor Unit PCB
Remote
Controller
Display
∗
Indoor unit LED
Display
Method of
Malfunction
Detection
The condition of the transmission circuit for indoor-outdoor signal transmission is detected.
Malfunction
Decision
Conditions
When the transmission circuit remains ON.
Supposed
Causes
"
Faulty indoor unit PCB
Troubleshooting
"
Replace the indoor unit PCB.