![Daikin FTK25JV1NB9 Service Manual Download Page 38](http://html1.mh-extra.com/html/daikin/ftk25jv1nb9/ftk25jv1nb9_service-manual_2459333038.webp)
Si04-115
General Functionality
Main Function
29
"
The frequency command for every zone is stated below.
(Please note that an operation will not carry out in the commanded frequency sometimes in
case a protection control like a freeze-protection etc. will be actuated.)
3. Required fan speed
"
Fan speed changes the rotation speed every time when a thermostat switches over ON and
OFF.
"
When the thermostat becomes Off, fan continues to operate 10 minutes more with low
speed so as to prevent recovery of humidity caused by reevaporation of the drain water, and
then stops.
Night set mode
The night set mode is activated when the off timer is set. It restricts the operation frequency, to
minimize the noise.
Room temperature
Room temp. zone
Command frequency
J type (25 / 35)
Room temp. < 18°C
A
0 / 0Hz
except A
34 / 34Hz
Room temp.
≥
18°C
A
0 / 0Hz
B
34 / 34Hz
D
40 / 40Hz
E
42 / 42Hz
F
42 / 42Hz
Fan rpm (thermostat ON)
J type (25 / 35)
Thermostat ON
970 / 980rpm
Thermostat OFF
800 / 800rpm
Thermostat ON and dry on
powerful operation
1050 / 1050rpm
Item
Description
Drawing
cooling The set temperature
stays on for one
hour, then
decreases slightly
for economical
operation.
heating The set temperature
stays on for one
hour, then increases
slightly for
economical
operation.
0,5˚C
0,5˚C
0,5˚C
temperature shift
A
A
B
B
A
B
temperature s1˚C
temperature s0.5˚C
temperature setting
operation stops
at the set hours
1 hour
30 min.
Timer operation
Night set circuit on
+0.5˚C temperature shift
Temperature setting remains
When the outside temperature is lower than 27˚C and the room
temperature is at the set temperature.
When the outside temperature is 27˚C or higher.
(R1913)
2˚C
Thermostat
setting
Timer operation
Night set circuit on
1 hour later
(R1914)