![Daikin FTK25JV1NB9 Service Manual Download Page 153](http://html1.mh-extra.com/html/daikin/ftk25jv1nb9/ftk25jv1nb9_service-manual_2459333153.webp)
Piping Diagram
Si04-115
144
Appendix
1.2.2 Heat Pump
RX25JVEA9, RX25JVET9, RX25JV1NB9
RX35JVEA9, RX35JVET9, RX35JV1NB9
VALVE
9.5CuT
FOUR WAY
ON:COOLING
7.9CuT
7.9CuT
OUTDOOR UNIT
MUFFLER
PROPELLER FAN
HEAT EXCHANGER
7.9CuT
7.9CuT
M
COMPRESSOR
9.5CuT
REVERSING
SOLENOID
VALVE
THERMISTOR
EXCHANGER
ACCUMLATOR
7.9CuT
7.9CuT
HEAT
OUTDOOR TEMPARATURE
THERMISTOR
REFRIGERANT FLOW
CAPILLARY TUBE 1
CAPILLARY TUBE 2
9.5CuT
COOLING
HEATING
6.4CuT
6.4CuT
WITH SERVICE PORT
GAS STOP VALVE
STOP VALVE
LIQUID
FIELD PIPING
FIELD PIPING
(6.4CuT)
(9.5CuT)
3D019959B
9.5CuT
VALVE
FOUR WAY
ON:COOLING
7.9CuT
7.9CuT
OUTDOOR UNIT
MUFFLER
PROPELLER FAN
HEAT EXCHANGER
7.9CuT
7.9CuT
M
COMPRESSOR
REVERSING
12.7CuT
SOLENOID
VALVE
THERMISTOR
7.9CuT
EXCHANGER
ACCUMLATOR
HEAT
OUTDOOR TEMPARATURE
THERMISTOR
REFRIGERANT FLOW
7.9CuT
9.5CuT
COOLING
HEATING
CAPILLARY TUBE
6.4CuT
WITH SERVICE PORT
GAS STOP VALVE
STOP VALVE
LIQUID
FIELD PIPING
FIELD PIPING
(6.4CuT)
(12.7CuT)
3D019957B