Operation Manual
SiBE06-708_A
67
Operation Manual
2.4
POWERFUL Operation
14
POWERFUL Operation
1.
•
•
•
2.
•
•
•
•
•
•
•
1, 2
POWERFUL operation quickly maximizes the
cooling (heating) effect in any operation mode.
You can get the maximum capacity.
To start POWERFUL
operation
POWERFUL operation ends in
20minutes. Then the system
automatically operates again with the
previous settings which were used
before POWERFUL operation.
Press “POWERFUL button”.
“ ” is displayed on the LCD.
When using POWERFUL operation,
there are some functions which are
not available.
To cancel POWERFUL
operation
Press “POWERFUL button”
again.
“ ” disappears from the LCD.
NOTE
Notes on POWERFUL operation
POWERFUL Operation cannot be used together with ECONO or QUIET Operation.
Priority is given to the function of whichever button is pressed last.
POWERFUL Operation can only be set when the unit is running. Pressing the operation
stop button causes the settings to be canceled, and the “ ” disappears from the LCD.
POWERFUL Operation will not increase the capacity of the air conditioner if the air
conditioner is already in operation with its maximum capacity demonstrated.
In COOL and HEAT mode
To maximize the cooling (heating) effect, the capacity of outdoor unit must be increased
and the airflow rate be fixed to the maximum setting.
The temperature and airflow settings are not variable.
In DRY mode
The temperature setting is lowered by 2.5˚C and the airflow rate is slightly increased.
In FAN mode
The airflow rate is fixed to the maximum setting.