![Daikin Floor Standing Type F-Series Service Manual Download Page 174](http://html1.mh-extra.com/html/daikin/floor-standing-type-f-series/floor-standing-type-f-series_service-manual_4065090174.webp)
Outdoor Unit - RK(X)S25/35F2V1B
SiBE06-708_A
163
Removal Procedure
2.2
Removal of Electrical Box
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the electrical
box.
Preparation
Remove the panels and
disconnect the connector for
the fan motor according to
“Removal of Outer Panels /
Fan Motor”.
1
Disconnect the 2
connectors for the
reactor.
2
Cut the clamp.
3
Disconnect the
connector for the
compressor [S30].
When reassembling, coil the
excessive lead wire and
hang the loop on the hook.
(R7214)
(R7215)
(R7216)
[S30]