![Daikin Floor Standing Type F-Series Service Manual Download Page 156](http://html1.mh-extra.com/html/daikin/floor-standing-type-f-series/floor-standing-type-f-series_service-manual_4065090156.webp)
Indoor Unit
SiBE06-708_A
145
Removal Procedure
3. Remove the service PCB.
Release the left hook first.
1
Unfasten the 2 hooks
of the lamp cover.
2
Unfasten the 2 hooks
of the service PCB.
3
Disconnect the
connector [S27] and
remove the service
PCB.
Step
Procedure
Points
Hook
Lamp cover
(R6790)
(R6791)
Service
PCB
Display
PCB
Hooks
Service PCB
(R6792)
(R6793)
[S27]