![Daikin Floor Standing Type F-Series Service Manual Download Page 197](http://html1.mh-extra.com/html/daikin/floor-standing-type-f-series/floor-standing-type-f-series_service-manual_4065090197.webp)
SiBE06-708_A
Outdoor Unit - RK(X)S25/35G2V1B
Removal Procedure
186
3.2
Removal of Electrical Box
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Disconnect the 2
connectors for the
reactor.
Preparation
Remove the panels and
disconnect the connector for
the fan motor according to
the “Removal of Outer
Panels / Fan Motor”.
2
Cut the clamps at 2
locations.
3
Disconnect the
connector for the
compressor [S30].
When reassembling, coil the
excessive lead wire and
hang the loop on the hook.
(R9338)
(R9339)
(R9340)
[S30]