![Daikin Floor Standing Type F-Series Service Manual Download Page 229](http://html1.mh-extra.com/html/daikin/floor-standing-type-f-series/floor-standing-type-f-series_service-manual_4065090229.webp)
SiBE06-708_A
Outdoor Unit - RK(X)S25/35G2V1B9
Removal Procedure
218
10
Disconnect the
connectors for the
magnetic relay [S50]
and for the forced
operation button PCB
[S100].
11
Disconnect the
connector for the filter
PCB [HL3] [HN3].
12
Release the harnesses
from the hook.
13
Release the harness for
the outdoor
temperature thermistor.
Step
Procedure
Points
(R11862)
[S100]
[S50]
[HL3]
[HN3]
(R11863)
(R11864)
(R11865)