Piping Diagrams
SiBE06-708_A
265
Appendix
1.2
Outdoor Unit
RKS25/35F2V1B
RKS25/35G2V1B, RKS25/35G2V1B9
M
9.5CuT
MUFFLER
9.5CuT
FIELD PIPING
FIELD PIPING
(6.4CuT)
(9.5CuT)
REFRIGERANT FLOW
COOLING
MUFFLER
7.9CuT
NORMALLY : OFF
COMPRESSOR
9.5CuT
ACCUMULATOR
7.9CuT
9.5CuT
PROPELLER FAN
9.5CuT
9.5CuT
7.0CuT
7.0CuT
OUTDOOR UNIT
HEAT EXCHANGER
4.8CuT
4.8CuT
6.4CuT 6.4CuT
6.4CuT
φ
. 4
.0
×
ID
. 2.0CuT
OUTDOOR TEMPERATURE
THERMISTOR
HEAT EXCHANGER
THERMISTOR
MOTOR OPERATED
VALVE
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
LIQUID STOP
VALVE
GAS STOP
VALVE
FOUR WAY
VALVE
DISCHARGE PIPE
THERMISTOR
3D047318G
9.5CuT
MUFFLER
COMPRESSOR
7.0CuT
9.5CuT
9.5CuT
HEAT EXCHANGER
REFRIGERANT FLOW
4.8CuT
(6.4CuT)
(9.5CuT)
PROPELLER FAN
M
FIELD PIPING
ACCUMULATOR
9.5CuT
6.4CuT
7.9CuT
6.4CuT
6.4CuT
FIELD PIPING
MUFFLER
7.0CuT
4.8CuT
OUTDOOR UNIT
COOLING
MUFFLER
9.5CuT
9.5CuT
7.9CuT
φ
.4.0
×
ID
. 2.0CuT
OUTDOOR TEMPERATURE
THERMISTOR
HEAT EXCHANGER
THERMISTOR
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
MOTOR OPERATED
VALVE
GAS STOP
VALVE
FOUR WAY
VALVE
NORMALLY:OFF
DISCHARGE PIPE
THERMISTOR
LIQUID STOP
VALVE
3D059589B