2/13
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Room
└─
Antifrost
1.4.1
[2-06]
R/W
0: Disabled
1: Enabled
1.4.2
[2-05]
R/W
4~16°C, step: 1°C
8°C
└─
Setpoint range
1.5.1
[3-07]
R/W
12~18°C, step: 1°C
12°C
1.5.2
[3-06]
R/W
18~30°C, step: 1°C
30°C
1.5.3
[3-09]
R/W
15~25°C, step: 1°C
15°C
1.5.4
[3-08]
R/W
25~35°C, step: 1°C
35°C
Room
1.6
[2-09]
R/W
-5~5°C, step: 0,5°C
0°C
1.7
[2-0A]
R/W
-5~5°C, step: 0,5°C
0°C
└─
Room comfort setpoint
1.9.1
[9-0A]
R/W
[3-07]~[3-06]°C, step: 0,5°C
23°C
1.9.2
[9-0B]
R/W
[3-09]~[3-08]°C, step: 0,5°C
23°C
Main zone
2.4
0: Fixed
1: WD heating, fixed cooling
2: Weather dependent
└─
Heating WD curve
2.5
[1-00]
R/W
-40~5°C, step: 1°C
-15°C
2.5
[1-01]
R/W
10~25°C, step: 1°C
15°C
2.5
[1-02]
R/W
[9-01]~[9-00], step: 1°C
[2-0C]=0:
35°C
[2-0C]=1:
45°C
[2-0C]=2:
65°C
2.5
[1-03]
R/W
[9-01]~min(45, [9-00])°C, step: 1°C
[2-0C]=0:
25°C
[2-0C]=1:
35°C
[2-0C]=2:
35°C
└─
Cooling WD curve
2.6
[1-06]
R/W
10~25°C, step: 1°C
20°C
2.6
[1-07]
R/W
25~43°C, step: 1°C
35°C
2.6
[1-08]
R/W
[9-03]~[9-02]°C, step: 1°C
22°C
2.6
[1-09]
R/W
[9-03]~[9-02]°C, step: 1°C
[2-0C]=0:
18°C
[2-0C]=1:
7°C
[2-0C]=2:
18°C
Main zone
2.7
[2-0C]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
└─
Setpoint range
2.8.1
[9-01]
R/W
15~37°C, step: 1°C
25°C
2.8.2
[9-00]
R/W
[2-0C]=2:
37~65, step: 1°C
65°C
[2-0C]
≠
2:
37~55, step: 1°C
55°C
2.8.3
[9-03]
R/W
5~18°C, step: 1°C
7°C
2.8.4
[9-02]
R/W
18~22°C, step: 1°C
22°C
Main zone
2.9
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
2.A
[C-05]
R/W
0: MMI requests (incl. quick logic)
1: 1 contact
2: 2 contacts
└─
Delta T
2.B.1
[1-0B]
[2-0C]
≠
2
R/W
[2-0C] =2
R/O
[2-0C]
≠
2 (Radiator):
3~10°C, step: 1°C
5°C
[2-0C]=2 (Radiator):
10°C
2.B.2
[1-0D]
R/W
3~10°C, step: 1°C
5°C
└─
Modulation
2.C.1
[8-05]
R/W
0: No
1: Yes
2.C.2
[8-06]
R/W
0~10°C, step: 1°C
5°C
└─
Shut off valve
High ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
Cooling comfort setpoint
Field settings table
Installer setting at variance with
default value
Activation
Room setpoint
Heating minimum
Heating maximum
Low ambient temp. for LWT main zone cooling WD curve.
High ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
Cooling minimum
Cooling maximum
Room sensor offset
Room sensor offset
Setpoint mode
Low ambient temp. for LWT main zone heating WD curve.
Heating comfort setpoint
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
Emitter type
Heating minimum
Heating maximum
Cooling minimum
Cooling maximum
Control
Thermostat type
Delta T heating
Delta T cooling
Modulation
Max modulation
4P634891-1 - 2021.03
(*1) *6V_(*2) *9W_
(*3) ETB*_(*4) ETV*_
(*5) *X*_(*6) *H*_
(*7) *18*_(*8) *23*
Summary of Contents for EPRA08EAV3
Page 289: ...13 13...
Page 290: ......
Page 291: ......
Page 292: ...4P634886 1 2021 03 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...