10
|
Configuration
Installer reference guide
193
EPRA08~W1 + ETVH/9W
Daikin Altherma 3 H MT F
4P634886-1 – 2021.03
9
Installer settings
Commissioning
Information
User settings
User profile
[9]
Installer settings
[9.1]
Configuration wizard
[9.2]
Domestic hot water
[9.3]
Backup heater
[9.5]
Emergency
[9.6]
Balancing
[9.7]
Water pipe freeze prevention
[9.8]
Benefit kWh power supply
[9.9]
Power consumption control
[9.A]
Energy metering
[9.B]
Sensors
[9.C]
Bivalent
[9.D]
Alarm output
[9.E]
Auto restart
[9.F]
Power saving function
[9.G]
Disable protections
[9.H]
Forced defrost
[9.I]
Overview field settings
[9.N]
Export MMI settings
[9.P]
Bizone kit
Configuration wizard
After first power ON of the system, the user interface will guide you using the
configuration wizard. This way you can set the most important initial settings. This
way the unit will be able to run properly. Afterwards, more detailed settings can be
done via the menu structure if required.
To restart the configuration wizard, go to
Installer
settings
>
Configuration wizard
[9.1].
Domestic hot water
Domestic hot water
The following setting determines if the system can prepare domestic hot water or
not, and which tank is used. This setting is read only.
#
Code
Description
[9.2.1]
[E‑05]
(a)
[E‑06]
(a)
[E‑07]
(a)
▪
Integrated
The backup heater will also be used for
domestic hot water heating.
(a)
Use the menu structure instead of the overview settings. Menu structure setting [9.2.1]
replaces the following 3 overview settings:
•
[E-05]: Can the system prepare domestic hot water?
•
[E-06]: Is a domestic hot water tank installed in the system?
•
[E-07]: What kind of domestic hot water tank is installed?
Summary of Contents for EPRA08EAV3
Page 289: ...13 13...
Page 290: ......
Page 291: ......
Page 292: ...4P634886 1 2021 03 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...