7 Installation
Installer reference guide
33
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351748-1D – 2016.02
X2M
X5M
35
34
1~
M
M2P
2
Fix the cable with cable ties to the cable tie mountings.
7.6.12
To connect the alarm output
1
Connect the alarm output cable to the appropriate terminals as
shown in the illustration below.
X2M
X5M
A4P
29
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
7.6.13
To connect the space heating ON/OFF
output
1
Connect the space heating ON/OFF output cable to the
appropriate terminals as shown in the illustration below.
X2M
X5M
A4P
29
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
7.6.14
To connect the changeover to external
heat source
1
Connect the changeover to external heat source cable to the
appropriate terminals as shown in the illustration below.
X2M
X5M
A4P
L
N
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
7.6.15
To connect the power consumption digital
inputs
1
Connect the power consumption digital inputs cable to the
appropriate terminals as shown in the illustration below.
X2M
X5M
A8P
S6S
S7S
S8S
S9S
1
23
4
5
a
a
Installation of EKRP1AHTA is required.
2
Fix the cable with cable ties to the cable tie mountings.
7.7
Finishing the indoor unit
installation
7.7.1
To fix the user interface cover to the
indoor unit
1
Make sure that the front panel is removed from the indoor unit.
See
"7.2.2 To open the indoor unit" on page 23
.
2
Plug the user interface cover into the hinges.