14 Technical data
Installer reference guide
79
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351748-1D – 2016.02
14.6
Technical specifications
14.6.1
Technical specifications: Indoor unit
Nominal capacity and nominal input
Indoor unit
Heating only
Condition 1
(a)
Heating capacity
Minimum
3.11 kW
Nominal
10.20 kW
Maximum
13.00 kW
Power input
Nominal
2.34 kW
COP
Nominal
4.35
Condition 2
(b)
Heating capacity
Minimum
2.47 kW
Nominal
9.29 kW
Maximum
11.90 kW
Power input
Nominal
2.82 kW
COP
Nominal
3.29
(a)
Entering water temperature (brine)/leaving water temperature (brine) 0°C/3°C – leaving water condenser 35°C (DT=5°C).
(b)
Entering water temperature (brine)/leaving water temperature (brine) 0°C/3°C – leaving water condenser 45°C (DT=5°C).
Technical specifications
Indoor unit
Heating only
Casing
Colour
White
Material
Precoated sheet metal
Dimensions
Packing (H×W×D)
1930×700×840 mm³
Unit (H×W×D)
1732×600×728 mm³
Weight
Machine weight
210 kg
Gross weight
222 kg
Packing
Material
Wood, carton, PE wrapping foil
Weight
12 kg
PED
Category of unit
Category I
Most critical part
Compressor
Ps*V
135 bar
Ps*DN
—
Main components
Water pump
Type
DC motor
Nr. of speeds
Inverter controlled
Nominal ESP
pump
Heating
(a)
39 kPa
Heating
(b)
46 kPa
Power Input
70 W
Water side heat exchanger
Type
Brazed plated
Quantity
1
Water volume
2.30 l
Minimum water flow rate
8.0 l/min
Nominal water
flow rate
Heating
(a)
29.2 l/min
Heating
(b)
26.6 l/min
Maximum water
flow rate
Heating
43.0 l/min
Insulation material
Green felt