5/7
Breadcrumb
Field code
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
Setting name
A.8
[3-00]
R/W
0: No
1: Yes
A.8
[3-01]
0
A.8
[3-02]
1
A.8
[3-03]
4
A.8
[3-04]
2
A.8
[3-05]
1
A.8
[3-06]
R/W
18~30°C, step: A.3.2.4
30°C
A.8
[3-07]
R/W
12~18°C, step: A.3.2.4
12°C
A.8
[3-08]
35
A.8
[3-09]
15
A.8
[4-00]
R/W
0: Disabled
1: Enabled
2: Only DHW
A.8
[4-01]
0
A.8
[4-02]
R/W
14~35°C, step: 1°C
35°C
A.8
[4-03]
3
A.8
[4-04]
2
A.8
[4-05]
0
A.8
[4-06]
0/1
A.8
[4-07]
R/W
0: No
1: Yes
A.8
[4-08]
R/W
0: No limitation
1: Continuous
2: Digital inputs
A.8
[4-09]
R/W
0: Current
1: Power
A.8
[4-0A]
0
A.8
[4-0B]
1
A.8
[4-0D]
3
A.8
[5-00]
R/W
0: Allowed
1: Not allowed
A.8
[5-01]
R/W
-15~35°C, step: 1°C
0°C
A.8
[5-02]
0
A.8
[5-03]
0
A.8
[5-04]
10
A.8
[5-05]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-06]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-07]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-08]
R/W
0~50 A, step: 1 A
50 A
A.8
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0A]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0B]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0C]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8
[5-0D]
R/O
4: 3PN,(1/2)
A.8
[5-0E]
1
A.8
[6-00]
R/W
2~20°C, step: 1°C
2°C
A.8
[6-01]
R/W
0~10°C, step: 1°C
2°C
A.8
[6-02]
0
A.8
[6-03]
R/W
0~10 kW, step: 0,2 kW
3 kW
A.8
[6-04]
R/W
0~10 kW, step: 0,2kW
3 kW
A.8
[6-05]
0
A.8
[6-06]
0
A.8
[6-07]
0
A.8
[6-08]
R/W
2~20°C, step: 1°C
10°C
A.8
[6-09]
0
A.8
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
60°C
A.8
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
A.8
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
A.8
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
A.8
[6-0E]
R/W
40~60°C, step: 1°C
60°C
A.8
[7-00]
0
A.8
[7-01]
2
A.8
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
A.8
[7-03]
R/W
0~6, step: 0,1
2,5
A.8
[7-04]
0
A.8
[7-05]
0
A.8
[8-00]
1
A.8
[8-01]
R/W
5~95 min, step: 5 min
30 min
A.8
[8-02]
R/W
0~10 hour, step: 0,5 hour
0,5 hour
A.8
[8-03]
50
A.8
[8-04]
R/W
0~95 min, step: 5 min
95 min
A.8
[8-05]
R/W
0: No
1: Yes
A.8
[8-06]
R/W
0~10°C, step: 1°C
3°C
A.8
[8-07]
18
Allow modulation of the LWT to control the room temp?
Leaving water temperature maximum modulation.
--
--
--
Maximum running time for domestic hot water operation.
Anti-recycling time.
--
Additional running time for the maximum running time.
What is the maximum temperature setpoint?
--
--
How many leaving water temperature zones are there?
PE factor
--
What is the hysteresis to be used in reheat mode?
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
What is the desired DHW production type?
--
What is the capacity of the backup heater step 1?
What is the capacity of the backup heater step 2?
--
--
--
What is the requested limit for DI3?
What is the requested limit for DI4?
What type of backup heater installation is used?
--
The temperature difference determining the heat pump ON temperature.
The temperature difference determining the heat pump OFF temperature.
What is the requested limit for DI1?
What is the requested limit for DI2?
What is the requested limit for DI3?
What is the requested limit for DI4?
What is the requested limit for DI1?
What is the requested limit for DI2?
Is backup heater or boiler operation allowed above equilibrium
temperature during space heating operation?
What is the equilibrium temperature for the building?
--
--
--
--
Which power limitation mode is required on the system?
-- (Do not change this value)
Below which outdoor temperature is heating allowed?
Which power limitation type is required?
--
--
What is the BUH operation mode?
--
--
--
--
Enable the second step of the backup heater?
--
--
What is the maximum desired room temperature in heating?
What is the mimimum desired room temperature in heating?
--
--
Is auto restart of the unit allowed?
--
--
--
(#) Setting is not applicable for this unit. Do not change the default value.
(##) Setting is not applicable for this unit.
*GSQH10S18AA9W / ThermaliaC12*
4P359382-1D - 2015.02