11.10
50B
Fixed Throttle ( 0.8) Mounting Instructions
When using the unit with a set pressure of 6 MPa or higher, if the pressure becomes unstable due to the
effects of contaminants, etc., mount the fixed throttle ( 0.8) provided as an accessory.
Check that there is no residual pressure before mounting it.
1.
Remove the hexagon socket head T plug (Rc 1/4).
2.
Mount the fixed throttle (NPTF1/16
0.8).
3.
Wrap sealing tape around the hexagon socket head T plug (Rc 1/4) and fit it as it was.
Hexagon socket head taper plug Rc 1/4
A
A
Section A - A
Fixed throttle ( 0.8)
NPTF1/16
Hexagon socket head taper plug