Inspection
Location/Item
Inspection
Timing/Interval
Inspection Instructions
Control unit
Once a month
Check if the ambient temperature has exceeded 40 C.
Electric wiring
Once every 6
months
Check that there are no cracks or breaks in the sheathing of the wiring.
Check that the ground is properly grounded.
Gear pump
As necessary
In the event of an oil leak from the oil seal, the pump must be replaced. Leaked
Threads/piping
Hose
As necessary
As necessary
Check that no threads or piping are loose or have oil leaks.
Check that there are no cracks or breaks, and that there is no damage.
11.5
45B
Cleaning/Replacement Work
Inspection Location/Item
Work
Work Instructions
Oil tank / Replacing the oil
Once a year
Replace the hydraulic oil at regular intervals.
Use for a long time without replacing the oil will adversely affect the
operation and life of the hydraulic equipment.
Oil cooler / Cleaning the core
Once a year
Disassemble and clean.
Oil filler port cum air breather
Once a year
Disassemble and clean.
Suction strainer
Once a year
Disassemble and clean.