CAUTION
Use hoses for the piping to this product.
Connect the hoses without any twisting.
In cases where excessive strain is likely to occur due to the weight of the hose, support the hose.
4.2
24B
Filling with Hydraulic Oil
Remove the cap of the filler port cum air breather by turning it counterclockwise, then pour clean
hydraulic oil (within NAS class 10) into the tank. The volume of oil should be that sufficient to bring the
float to between the red line and yellow line.
6.1 Product Specifications
CAUTION
6.1 Product Specifications
Running the product while the tank is not filled with oil will cause seizure and/or wear of the pump,
leading to breakage. Be sure to check the oil level.
During the initial operation of the machine, oil is supplied to the hydraulic circuits at the machine side
and the oil in the tank may decrease. Add oil to bring the height of the oil level to within the stipulated
range.
Depending on the volumetric capacity of the hydraulic circuits at the machine side, the fluctuations in oil
level in the tank may become large, and oil may overflow from the tank or the oil level may drop. Adjust
while watching the oil level gauge to achieve the optimum oil level.
Oil level gauge
Oil filler port cum air breather